| /* |
| * s2mu205_fuelgauge.c - S2MU205 Fuel Gauge Driver |
| * |
| * Copyright (C) 2018 Samsung Electronics, Inc. |
| * |
| * This program is free software; you can redistribute it and/or |
| * modify it under the terms of the GNU General Public License |
| * as published by the Free Software Foundation; either version 2 |
| * of the License, or (at your option) any later version. |
| * |
| * This program is distributed in the hope that it will be useful, |
| * but WITHOUT ANY WARRANTY; without even the implied warranty of |
| * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the |
| * GNU General Public License for more details. |
| * |
| * You should have received a copy of the GNU General Public License |
| * along with this program. If not, see <http://www.gnu.org/licenses/>. |
| * |
| */ |
| |
| #define SINGLE_BYTE 1 |
| #define TABLE_SIZE 22 |
| |
| #include "include/fuelgauge/s2mu205_fuelgauge.h" |
| #include <linux/of_gpio.h> |
| |
| static enum power_supply_property s2mu205_fuelgauge_props[] = { |
| }; |
| |
| static int s2mu205_get_vbat(struct s2mu205_fuelgauge_data *fuelgauge); |
| static int s2mu205_get_ocv(struct s2mu205_fuelgauge_data *fuelgauge); |
| static int s2mu205_get_current(struct s2mu205_fuelgauge_data *fuelgauge); |
| static int s2mu205_get_avgcurrent(struct s2mu205_fuelgauge_data *fuelgauge); |
| static int s2mu205_get_avgvbat(struct s2mu205_fuelgauge_data *fuelgauge); |
| |
| static int s2mu205_read_reg_byte(struct i2c_client *client, int reg, void *data) |
| { |
| int ret = 0; |
| int cnt = 0; |
| |
| ret = i2c_smbus_read_byte_data(client, reg); |
| if (ret < 0) { |
| while (ret < 0 && cnt < 5) { |
| ret = i2c_smbus_read_byte_data(client, reg); |
| cnt++; |
| dev_err(&client->dev, |
| "%s: I2C read Incorrect! reg:0x%x, data:0x%x, cnt:%d\n", |
| __func__, reg, *(u8 *)data, cnt); |
| } |
| if (cnt == 5) |
| dev_err(&client->dev, |
| "%s: I2C read Failed reg:0x%x, data:0x%x\n", |
| __func__, reg, *(u8 *)data); |
| } |
| *(u8 *)data = (u8)ret; |
| |
| return ret; |
| } |
| |
| static int s2mu205_write_and_verify_reg_byte(struct i2c_client *client, int reg, u8 data) |
| { |
| int ret, i = 0; |
| int i2c_corrupted_cnt = 0; |
| u8 temp = 0; |
| |
| ret = i2c_smbus_write_byte_data(client, reg, data); |
| if (ret < 0) { |
| for (i = 0; i < 3; i++) { |
| ret = i2c_smbus_write_byte_data(client, reg, data); |
| if (ret >= 0) |
| break; |
| } |
| |
| if (i >= 3) |
| dev_err(&client->dev, "%s: Error(%d)\n", __func__, ret); |
| } |
| |
| /* Skip non-writable registers */ |
| if ((reg == 0xee) || (reg == 0xef) || (reg == 0xf2) || (reg == 0xf3) || |
| (reg == 0x0C) || (reg == 0x1e) || (reg == 0x1f) || (reg == 0x27)) { |
| return ret; |
| } |
| |
| s2mu205_read_reg_byte(client, reg, &temp); |
| while ((temp != data) && (i2c_corrupted_cnt < 5)) { |
| dev_err(&client->dev, |
| "%s: I2C write Incorrect! REG: 0x%x Expected: 0x%x Real-Value: 0x%x\n", |
| __func__, reg, data, temp); |
| ret = i2c_smbus_write_byte_data(client, reg, data); |
| s2mu205_read_reg_byte(client, reg, &temp); |
| i2c_corrupted_cnt++; |
| } |
| |
| if (i2c_corrupted_cnt == 5) |
| dev_err(&client->dev, |
| "%s: I2C write failed REG: 0x%x Expected: 0x%x\n", |
| __func__, reg, data); |
| |
| return ret; |
| } |
| |
| static int s2mu205_update_reg_byte(struct i2c_client *client, int reg, u8 val, u8 mask) |
| { |
| int ret; |
| u8 old_val, new_val; |
| |
| ret = s2mu205_read_reg_byte(client, reg, &old_val); |
| if (ret >= 0) { |
| new_val = (val & mask) | (old_val & (~mask)); |
| ret = s2mu205_write_and_verify_reg_byte(client, reg, new_val); |
| } |
| |
| return ret; |
| } |
| |
| static int s2mu205_write_reg(struct i2c_client *client, int reg, u8 *buf) |
| { |
| #if SINGLE_BYTE |
| int ret = 0; |
| s2mu205_write_and_verify_reg_byte(client, reg, buf[0]); |
| s2mu205_write_and_verify_reg_byte(client, reg+1, buf[1]); |
| #else |
| int ret, i = 0; |
| |
| ret = i2c_smbus_write_i2c_block_data(client, reg, 2, buf); |
| if (ret < 0) { |
| for (i = 0; i < 3; i++) { |
| ret = i2c_smbus_write_i2c_block_data(client, reg, 2, buf); |
| if (ret >= 0) |
| break; |
| } |
| |
| if (i >= 3) |
| dev_err(&client->dev, "%s: Error(%d)\n", __func__, ret); |
| } |
| #endif |
| return ret; |
| } |
| |
| static int s2mu205_read_reg(struct i2c_client *client, int reg, u8 *buf) |
| { |
| |
| #if SINGLE_BYTE |
| int ret = 0; |
| u8 data1 = 0, data2 = 0; |
| s2mu205_read_reg_byte(client, reg, &data1); |
| s2mu205_read_reg_byte(client, reg+1, &data2); |
| buf[0] = data1; |
| buf[1] = data2; |
| #else |
| int ret = 0, i = 0; |
| |
| ret = i2c_smbus_read_i2c_block_data(client, reg, 2, buf); |
| if (ret < 0) { |
| for (i = 0; i < 3; i++) { |
| ret = i2c_smbus_read_i2c_block_data(client, reg, 2, buf); |
| if (ret >= 0) |
| break; |
| } |
| |
| if (i >= 3) |
| dev_err(&client->dev, "%s: Error(%d)\n", __func__, ret); |
| } |
| #endif |
| return ret; |
| } |
| |
| static void s2mu205_fg_test_read(struct i2c_client *client) |
| { |
| static int reg_list[] = { |
| 0x04, 0x05, 0x06, 0x07, 0x08, 0x09, 0x0A, 0x0B, 0x0E, 0x0F, |
| 0x10, 0x11, 0x14, 0x1A, 0x1B, 0x1E, 0x1F, 0x24, 0x25, 0x26, |
| 0x27, 0x28, 0x29, 0x40, 0x41, 0x43, 0x44, 0x45, 0x48, 0x4A, |
| 0x4B, 0x50, 0x51, 0x52, 0x53, 0x58, 0x59, 0x5A, 0x5B, 0x5C, |
| 0x67, 0x88, 0x89 |
| }; |
| u8 data = 0; |
| char str[1016] = {0,}; |
| int i = 0, reg_list_size = 0; |
| |
| reg_list_size = ARRAY_SIZE(reg_list); |
| for (i = 0; i < reg_list_size; i++) { |
| s2mu205_read_reg_byte(client, reg_list[i], &data); |
| sprintf(str+strlen(str), "0x%02x:0x%02x, ", reg_list[i], data); |
| } |
| |
| /* print buffer */ |
| pr_info("[FG]%s: %s\n", __func__, str); |
| } |
| |
| int check_current_level(struct s2mu205_fuelgauge_data *fuelgauge) |
| { |
| int ret_val = 500; |
| int temp = 0; |
| |
| if (fuelgauge->cable_type == SEC_BATTERY_CABLE_USB) { |
| return ret_val; |
| } |
| |
| /* topoff current * 1.6 except USB */ |
| temp = fuelgauge->topoff_current * 16; |
| ret_val = temp / 10; |
| |
| return ret_val; |
| } |
| |
| static void s2mu205_restart_gauging(struct s2mu205_fuelgauge_data *fuelgauge) |
| { |
| u8 data[2]; |
| |
| pr_info("%s: Re-calculate SOC and voltage\n", __func__); |
| |
| mutex_lock(&fuelgauge->fg_lock); |
| |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x1E, 0x0F); |
| |
| msleep(300); |
| |
| #if (TEMP_COMPEN) |
| /* Need to re-init temperature compensation */ |
| fuelgauge->init_start = 1; |
| /* Make saved UI SOC invalid. Set S2MU205_REG_RSOC_R + 1 reg. */ |
| data[0] = 0; |
| data[1] = 1; |
| s2mu205_write_reg(fuelgauge->i2c, S2MU205_REG_RSOC_R, data); |
| #endif |
| |
| mutex_unlock(&fuelgauge->fg_lock); |
| } |
| |
| static void s2mu205_reset_fg(struct s2mu205_fuelgauge_data *fuelgauge) |
| { |
| int i; |
| |
| mutex_lock(&fuelgauge->fg_lock); |
| |
| /* step 0: [Surge test] initialize register of FG */ |
| #if defined(CONFIG_BATTERY_AGE_FORECAST) |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x90, |
| (fuelgauge->age_data_info[fuelgauge->fg_age_step].batcap[0] | 0x01)); |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x91, |
| fuelgauge->age_data_info[fuelgauge->fg_age_step].batcap[1]); |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x10, |
| fuelgauge->age_data_info[fuelgauge->fg_age_step].batcap[2]); |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x11, |
| fuelgauge->age_data_info[fuelgauge->fg_age_step].batcap[3]); |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x13, |
| fuelgauge->age_data_info[fuelgauge->fg_age_step].volt_mode_tunning); |
| #else |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x90, (fuelgauge->info.batcap[0] | 0x01); |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x91, fuelgauge->info.batcap[1]); |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x10, fuelgauge->info.batcap[2]); |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x11, fuelgauge->info.batcap[3]); |
| #endif |
| #if defined(CONFIG_BATTERY_AGE_FORECAST) |
| for(i = 0x92; i <= 0xe9; i++) { |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, i, |
| fuelgauge->age_data_info[fuelgauge->fg_age_step].battery_table3[i - 0x92]); |
| } |
| for(i = 0xea; i <= 0xff; i++) { |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, i, |
| fuelgauge->age_data_info[fuelgauge->fg_age_step].battery_table4[i - 0xea]); |
| } |
| #else |
| for (i = 0x92; i <= 0xe9; i++) |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, i, fuelgauge->info.battery_table3[i - 0x92]); |
| for (i = 0xea; i <= 0xff; i++) |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, i, fuelgauge->info.battery_table4[i - 0xea]); |
| #endif |
| |
| #if defined(CONFIG_BATTERY_AGE_FORECAST) |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x44, |
| fuelgauge->age_data_info[fuelgauge->fg_age_step].accum[0]); |
| s2mu205_update_reg_byte(fuelgauge->i2c, 0x45, |
| fuelgauge->age_data_info[fuelgauge->fg_age_step].accum[1], 0x0F); |
| #else |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x44, fuelgauge->info.accum[0]); |
| s2mu205_update_reg_byte(fuelgauge->i2c, 0x45, fuelgauge->info.accum[1], 0x0F); |
| #endif |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x14, 0x67); |
| |
| s2mu205_update_reg_byte(fuelgauge->i2c, 0x4B, 0x00, 0x70); |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x4A, 0x10); |
| |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x40, 0x08); |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x41, 0x04); |
| |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x5C, 0x1A); |
| |
| /* Dumpdone. Re-calculate SOC */ |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x1E, 0x0F); |
| msleep(300); |
| |
| /* If it was voltage mode, recover it */ |
| if (fuelgauge->mode == HIGH_SOC_VOLTAGE_MODE) { |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x4A, 0xFF); |
| s2mu205_update_reg_byte(fuelgauge->i2c, 0x4B, 0x70, 0x70); |
| } |
| |
| mutex_unlock(&fuelgauge->fg_lock); |
| |
| pr_info("%s: Reset FG completed\n", __func__); |
| } |
| |
| static int s2mu205_fix_rawsoc_reset_fg(struct s2mu205_fuelgauge_data *fuelgauge) |
| { |
| int ret = 0, ui_soc = 0, f_soc = 0; |
| u8 data; |
| struct power_supply *psy; |
| union power_supply_propval value; |
| |
| psy = power_supply_get_by_name("battery"); |
| if (!psy) |
| return -EINVAL; |
| ret = power_supply_get_property(psy, POWER_SUPPLY_PROP_CAPACITY, &value); |
| if (ret < 0) |
| pr_err("%s: Fail to execute property\n", __func__); |
| dev_info(&fuelgauge->i2c->dev, "%s: UI SOC = %d\n", __func__, value.intval); |
| |
| ui_soc = value.intval; |
| f_soc = (ui_soc << 8) / 100; |
| |
| if (f_soc > 0xFF) |
| f_soc = 0xFF; |
| |
| f_soc |= 0x1; |
| |
| data = (u8)f_soc; |
| |
| /* Set rawsoc fix & enable */ |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x29, data); |
| |
| #if defined(CONFIG_BATTERY_AGE_FORECAST) |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x0E, |
| fuelgauge->age_data_info[fuelgauge->fg_age_step].batcap[0]); |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x0F, |
| fuelgauge->age_data_info[fuelgauge->fg_age_step].batcap[1]); |
| #else |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x0E, fuelgauge->info.batcap[0]); |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x0F, fuelgauge->info.batcap[1]); |
| #endif |
| /* After battery capacity update, set BATCAP_OCV_EN(0x0C[6]=1) */ |
| s2mu205_update_reg_byte(fuelgauge->i2c, 0x0C, 0x40, 0x40); |
| |
| /* Parameter write */ |
| s2mu205_reset_fg(fuelgauge); |
| |
| /* Disable rawsoc fix */ |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x29, 0x00); |
| |
| dev_info(&fuelgauge->i2c->dev, "%s: Finish\n", __func__); |
| |
| return ret; |
| } |
| |
| /* Set model data version for next boot up initializing fuelgauge */ |
| static void s2mu205_fg_reset_capacity_by_jig_connection(struct s2mu205_fuelgauge_data *fuelgauge) |
| { |
| /* TODO : model data version check */ |
| } |
| |
| #if (TEMP_COMPEN) |
| static bool s2mu205_get_vm_status(struct s2mu205_fuelgauge_data *fuelgauge) |
| { |
| /* Voltage Mode operation state */ |
| u8 data = 0; |
| |
| s2mu205_read_reg_byte(fuelgauge->i2c, S2MU205_REG_STATUS, &data); |
| |
| return (data & (1 << 6)) ? true : false; |
| } |
| |
| static int s2mu205_get_comp_socr(int temperature, int avg_curr) |
| { |
| int comp_socr = 0; |
| int t_socr = 0; |
| int i_socr = (-333) * avg_curr; |
| |
| if (temperature <= 0) |
| t_socr = ((-223) * temperature + 15500) / 1000; |
| else if (temperature <= 200) |
| t_socr = ((-75) * temperature + 15500) / 1000; |
| |
| comp_socr = ((t_socr + 1) * i_socr) / 100000; |
| |
| comp_socr = comp_socr - (comp_socr % 5); |
| |
| if (comp_socr > 80) |
| comp_socr = 80; |
| else if (comp_socr < 0) |
| comp_socr = 0; |
| |
| pr_info("%s: SOCr = %d, T_SOCr = %d, I_SOCr = %d\n", __func__, |
| comp_socr, t_socr, i_socr / 100000); |
| |
| return comp_socr; |
| } |
| |
| static int s2mu205_get_soc_map(struct s2mu205_fuelgauge_data *fuelgauge, |
| bool bat_charging, int comp_socr) |
| { |
| int soc_map = 0; |
| |
| if (bat_charging) { |
| if (fuelgauge->soc0i >= 9950) |
| soc_map = 10000; |
| else |
| soc_map = |
| ((10040 - fuelgauge->socni) * (fuelgauge->rsoc - fuelgauge->soc0i)) / |
| (10000 - fuelgauge->soc0i) + fuelgauge->socni; |
| } else { |
| if (fuelgauge->soc0i < ((100 * comp_socr) + 50)) |
| soc_map = 0; |
| else |
| soc_map = |
| (fuelgauge->socni * (fuelgauge->rsoc - fuelgauge->soc0i)) / |
| (fuelgauge->soc0i - (100 * comp_socr)) + fuelgauge->socni; |
| } |
| |
| if (soc_map > 10000) |
| soc_map = 10000; |
| else if (soc_map < 0) |
| soc_map = 0; |
| |
| return soc_map; |
| } |
| |
| static void s2mu205_temperature_compensation(struct s2mu205_fuelgauge_data *fuelgauge) |
| { |
| int soc_map = 0; |
| int ui_soc = 0; |
| u8 data[2]; |
| |
| fuelgauge->comp_socr = |
| s2mu205_get_comp_socr(fuelgauge->temperature, fuelgauge->avg_curr); |
| |
| if (fuelgauge->init_start) { |
| fuelgauge->flag_mapping = true; |
| fuelgauge->pre_comp_socr = fuelgauge->comp_socr; |
| fuelgauge->pre_vm_status = fuelgauge->vm_status; |
| } |
| |
| if ((fuelgauge->pre_comp_socr != fuelgauge->comp_socr) || |
| (fuelgauge->pre_bat_charging != fuelgauge->bat_charging) || |
| (fuelgauge->pre_vm_status != fuelgauge->vm_status) || |
| (fuelgauge->pre_is_charging != fuelgauge->is_charging)) |
| fuelgauge->flag_mapping = true; |
| |
| if (fuelgauge->flag_mapping == true) { |
| if (fuelgauge->init_start) { |
| if (fuelgauge->temperature < fuelgauge->low_temp_limit) { |
| s2mu205_read_reg(fuelgauge->i2c, S2MU205_REG_RSOC_R, data); |
| |
| if (data[1] == 0) { |
| ui_soc = (data[1] << 8) | (data[0]); |
| |
| pr_info("%s: temperature is low. use saved UI SOC(%d)" |
| " for mapping, data[1] = 0x%02x, data[0] = 0x%02x\n", |
| __func__, ui_soc, data[1], data[0]); |
| |
| fuelgauge->ui_soc = ui_soc; |
| |
| /* UI SOC unit is 1% */ |
| ui_soc = ui_soc * 100; |
| |
| fuelgauge->socni = ui_soc; |
| fuelgauge->soc0i = fuelgauge->rsoc; |
| } else { |
| pr_info("%s: temperature is low. but UI SOC is not saved\n", |
| __func__); |
| |
| fuelgauge->socni = fuelgauge->rsoc; |
| fuelgauge->soc0i = fuelgauge->rsoc; |
| } |
| } else { |
| fuelgauge->socni = fuelgauge->rsoc; |
| fuelgauge->soc0i = fuelgauge->rsoc; |
| } |
| } else { |
| /* After mapping, SOC_R is maintained. |
| If mapping occurs continuously, SOC is not changed. |
| So SOC_R need to be updated before mapping. |
| */ |
| fuelgauge->soc_r = s2mu205_get_soc_map(fuelgauge, |
| fuelgauge->pre_bat_charging, fuelgauge->pre_comp_socr); |
| |
| fuelgauge->socni = fuelgauge->soc_r; |
| fuelgauge->soc0i = fuelgauge->rsoc; |
| } |
| } |
| |
| soc_map = s2mu205_get_soc_map(fuelgauge, |
| fuelgauge->bat_charging, fuelgauge->comp_socr); |
| |
| #if !defined(INC_OK_EN) |
| /* Use is_charging flag for prevent SOC increase when not charging */ |
| if ((fuelgauge->is_charging == false) && (soc_map > fuelgauge->soc_r)) { |
| if(fuelgauge->init_start) |
| fuelgauge->soc_r = soc_map; |
| else |
| pr_info("%s: Not charging, do not reflect SOC increase. soc_map = %d, soc_r = %d\n", |
| __func__, soc_map, fuelgauge->soc_r); |
| } |
| else |
| fuelgauge->soc_r = soc_map; |
| #else |
| fuelgauge->soc_r = soc_map; |
| #endif |
| |
| if (fuelgauge->vm_status && (fuelgauge->soc_r > fuelgauge->rsoc) && |
| (fuelgauge->temperature <= fuelgauge->low_temp_limit)) |
| fuelgauge->soc_r = fuelgauge->rsoc; |
| |
| #if !(BATCAP_LEARN) |
| pr_info("%s: SOC_M = %d, Chg_stat = %d, VM = %d, flag_mapping = %d, avgCURR = %d, avgTEMP = %d, " |
| "SOCni = %d, SOC0i = %d, SOCr = %d, SOC_R = %d\n", |
| __func__, fuelgauge->rsoc, fuelgauge->bat_charging, fuelgauge->vm_status, |
| fuelgauge->flag_mapping, fuelgauge->avg_curr, fuelgauge->temperature, |
| fuelgauge->socni, fuelgauge->soc0i, fuelgauge->comp_socr, fuelgauge->soc_r); |
| #endif |
| fuelgauge->init_start = 0; |
| fuelgauge->pre_comp_socr = fuelgauge->comp_socr; |
| fuelgauge->pre_vm_status = fuelgauge->vm_status; |
| fuelgauge->pre_is_charging = fuelgauge->is_charging; |
| fuelgauge->pre_bat_charging = fuelgauge->bat_charging; |
| fuelgauge->flag_mapping = false; |
| |
| /* Save UI SOC for maintain SOC, after low temperature reset */ |
| data[0] = fuelgauge->ui_soc; |
| data[1] = 0; |
| s2mu205_write_reg(fuelgauge->i2c, S2MU205_REG_RSOC_R, data); |
| |
| /* TODO: Print UI SOC & saved value for debugging */ |
| s2mu205_read_reg(fuelgauge->i2c, S2MU205_REG_RSOC_R, data); |
| ui_soc = (data[1] << 8) | (data[0]); |
| pr_info("%s: saved UI SOC = %d, data[1] = 0x%02x, data[0] = 0x%02x\n", |
| __func__, ui_soc, data[1], data[0]); |
| } |
| #endif |
| |
| #if (BATCAP_LEARN) |
| static int s2mu205_get_batcap_ocv(struct s2mu205_fuelgauge_data *fuelgauge) |
| { |
| u8 data[2]; |
| u32 batcap_ocv = 0; |
| |
| if (s2mu205_read_reg(fuelgauge->i2c, S2MU205_REG_RBATCAP_NEW, data) < 0) |
| return -EINVAL; |
| |
| dev_dbg(&fuelgauge->i2c->dev, "%s: data0 (%d) data1 (%d) \n", __func__, data[0], data[1]); |
| batcap_ocv = (data[0] + (data[1] << 8)) >> 2; |
| |
| return batcap_ocv; |
| } |
| |
| static int s2mu205_get_cycle(struct s2mu205_fuelgauge_data *fuelgauge) |
| { |
| u8 data[2]; |
| u16 compliment, cycle; |
| |
| mutex_lock(&fuelgauge->fg_lock); |
| |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, S2MU205_REG_MONOUT_SEL, 0x27); |
| msleep(50); |
| |
| if (s2mu205_read_reg(fuelgauge->i2c, S2MU205_REG_MONOUT, data) < 0) |
| goto err; |
| compliment = (data[1] << 8) | (data[0]); |
| cycle = compliment; |
| |
| mutex_unlock(&fuelgauge->fg_lock); |
| |
| return cycle; |
| err: |
| mutex_unlock(&fuelgauge->fg_lock); |
| return -EINVAL; |
| } |
| |
| void s2mu205_batcap_learning(struct s2mu205_fuelgauge_data *fuelgauge) |
| { |
| int bat_w = 0; |
| u8 data[2]; |
| int range = (BAT_L_CON[5] == 0) ? 900:800; |
| int gap_cap = 0; |
| |
| gap_cap = (fuelgauge->capcc * 1000) / fuelgauge->batcap_ocv; |
| |
| if ((gap_cap > range) && (gap_cap < 1100)) { |
| if (BAT_L_CON[6]) |
| bat_w = ((fuelgauge->batcap_ocv * 75) + (fuelgauge->capcc * 25)) / 100; |
| else |
| bat_w = ((fuelgauge->batcap_ocv * 90) + (fuelgauge->capcc * 10)) / 100; |
| |
| if (BAT_L_CON[7]) { |
| fuelgauge->batcap_ocv_fin = bat_w; |
| bat_w = bat_w << 2; |
| data[1] = (u8)((bat_w >> 8) & 0x00ff); |
| data[0] = (u8)(bat_w & 0x00ff); |
| /* BATCAP_OCV_EN = 1*/ |
| data[0] = data[0] | 0x01; |
| |
| mutex_lock(&fuelgauge->fg_lock); |
| s2mu205_write_reg(fuelgauge->i2c, S2MU205_REG_RBATCAP_NEWIN, data); |
| mutex_unlock(&fuelgauge->fg_lock); |
| } |
| } |
| |
| pr_info("%s: gap_cap = %d, capcc = %d, batcap_ocv = %d, bat_w = %d\n", |
| __func__, gap_cap, fuelgauge->capcc, fuelgauge->batcap_ocv, bat_w); |
| } |
| |
| static int s2mu205_get_cap_cc(struct s2mu205_fuelgauge_data *fuelgauge) |
| { |
| u8 data1 = 0, data0 = 0; |
| int cap_cc = 0; |
| |
| s2mu205_read_reg_byte(fuelgauge->i2c, S2MU205_REG_CAPCC, &data0); |
| s2mu205_read_reg_byte(fuelgauge->i2c, S2MU205_REG_CAPCC + 1, &data1); |
| cap_cc = (data1 << 8) | data0; |
| if (cap_cc & (1 << 15)) { |
| cap_cc = (~cap_cc) + 1; |
| cap_cc = cap_cc / 2; |
| cap_cc = cap_cc * (-1); |
| } |
| else |
| cap_cc /= 2; |
| |
| return cap_cc; |
| } |
| |
| static int s2mu205_get_soh(struct s2mu205_fuelgauge_data *fuelgauge) |
| { |
| u8 data1 = 0, data0 = 0; |
| int original = 0, ret = -1; |
| int batcap_ocv = s2mu205_get_batcap_ocv(fuelgauge); |
| |
| s2mu205_read_reg_byte(fuelgauge->i2c, S2MU205_REG_BATCAP, &data0); |
| s2mu205_read_reg_byte(fuelgauge->i2c, S2MU205_REG_BATCAP + 1, &data1); |
| original = (data1 << 8) | data0; |
| |
| if (original != 0) { |
| ret = (batcap_ocv * 100) / original; |
| |
| if (ret > 100) |
| ret = 100; |
| } else |
| ret = 100; |
| |
| pr_info("%s: original batcap = %d, new_batcap = %d, soh = %d\n", |
| __func__, original, batcap_ocv, ret); |
| |
| return ret; |
| } |
| #endif |
| |
| #if (BATCAP_LEARN) || (TEMP_COMPEN) |
| static bool s2mu205_get_bat_charging(struct s2mu205_fuelgauge_data *fuelgauge) |
| { |
| u8 data = 0; |
| |
| s2mu205_read_reg_byte(fuelgauge->i2c, S2MU205_REG_STATUS, &data); |
| |
| return (data & (1 << 5)) ? true : false; |
| } |
| |
| static int s2mu205_get_fullcharge_cap(struct s2mu205_fuelgauge_data *fuelgauge) |
| { |
| int ret = -1; |
| int batcap_ocv = s2mu205_get_batcap_ocv(fuelgauge); |
| |
| ret = ((100 - fuelgauge->comp_socr) * batcap_ocv) / 100; |
| |
| return ret; |
| } |
| |
| static int s2mu205_get_remaining_cap(struct s2mu205_fuelgauge_data *fuelgauge) |
| { |
| int ret = -1; |
| int fcc = s2mu205_get_fullcharge_cap(fuelgauge); |
| |
| ret = (fuelgauge->soc_r) * fcc / 10000; |
| |
| pr_info("%s: fcc = %d, remaining_cap = %d\n", __func__, fcc, ret); |
| |
| return ret; |
| } |
| #endif |
| |
| static int s2mu205_set_temperature(struct s2mu205_fuelgauge_data *fuelgauge, |
| int temperature) |
| { |
| /* There's No need to set Temperature value */ |
| return temperature; |
| } |
| |
| static int s2mu205_get_temperature(struct s2mu205_fuelgauge_data *fuelgauge) |
| { |
| u8 data[2]; |
| u16 compliment; |
| int temperature = 0; |
| |
| mutex_lock(&fuelgauge->fg_lock); |
| |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, S2MU205_REG_MONOUT_SEL, 0x18); |
| if (s2mu205_read_reg(fuelgauge->i2c, S2MU205_REG_MONOUT, data) < 0) |
| goto err; |
| |
| mutex_unlock(&fuelgauge->fg_lock); |
| compliment = (data[1] << 8) | (data[0]); |
| |
| /* data[] store 2's compliment format number */ |
| if (compliment & (0x1 << 15)) { |
| /* Negative */ |
| temperature = -1 * ((~compliment & 0xFFFF) + 1); |
| } else { |
| temperature = compliment & 0x7FFF; |
| } |
| temperature = ((temperature * 100) >> 8)/10; |
| |
| pr_info("%s: temperature (%d)\n", __func__, temperature); |
| |
| return temperature; |
| err: |
| mutex_unlock(&fuelgauge->fg_lock); |
| return -ERANGE; |
| |
| } |
| |
| static int s2mu205_get_rawsoc(struct s2mu205_fuelgauge_data *fuelgauge) |
| { |
| u8 data[2], check_data[2]; |
| u16 compliment; |
| u8 por_state = 0; |
| u8 reg_1E = 0; |
| u8 reg_OTP_52 = 0, reg_OTP_53 = 0; |
| u8 temp = 0; |
| #if defined(CONFIG_CHARGER_S2MU205) |
| bool charging_enabled = false; |
| #endif |
| int ret = 0; |
| struct power_supply *psy; |
| union power_supply_propval value; |
| int float_voltage = 0; |
| int avg_current = 0, avg_vbat = 0, vbat = 0, curr = 0; |
| u8 fg_mode_reg = 0; |
| #if (BATCAP_LEARN) |
| int BATCAP_L_VBAT; |
| #endif |
| int i = 0; |
| |
| s2mu205_read_reg_byte(fuelgauge->i2c, 0x1E, ®_1E); |
| s2mu205_read_reg_byte(fuelgauge->i2c, 0x1F, &por_state); |
| s2mu205_read_reg_byte(fuelgauge->i2c, 0x52, ®_OTP_52); |
| s2mu205_read_reg_byte(fuelgauge->i2c, 0x53, ®_OTP_53); |
| |
| dev_err(&fuelgauge->i2c->dev, "%s: OTP 52(%02x) 53(%02x), current 52(%02x) 53(%02x), " |
| "0x1F(%02x), 0x1E(%02x)\n", __func__, fuelgauge->reg_OTP_52, fuelgauge->reg_OTP_53, |
| reg_OTP_52, reg_OTP_53, por_state, reg_1E); |
| |
| #if defined(CONFIG_BATTERY_AGE_FORECAST) |
| if((((por_state != 0x00) || (reg_1E != 0x03)) && (fuelgauge->age_reset_status == 0)) || |
| #else |
| if(((por_state != 0x00) || (reg_1E != 0x03)) || |
| #endif |
| (fuelgauge->probe_done == true && |
| (fuelgauge->reg_OTP_52 != reg_OTP_52 || fuelgauge->reg_OTP_53 != reg_OTP_53))) { |
| /* check charging enable */ |
| #if defined(CONFIG_CHARGER_S2MU205) |
| psy = power_supply_get_by_name("s2mu205-charger"); |
| if (!psy) |
| return -EINVAL; |
| ret = power_supply_get_property(psy, POWER_SUPPLY_PROP_CHARGING_ENABLED, &value); |
| if (ret < 0) |
| pr_err("%s: Fail to execute property\n", __func__); |
| charging_enabled = value.intval; |
| |
| value.intval = SEC_BAT_CHG_MODE_CHARGING_OFF; |
| psy = power_supply_get_by_name("s2mu205-charger"); |
| if (!psy) |
| return -EINVAL; |
| ret = power_supply_set_property(psy, POWER_SUPPLY_PROP_CHARGING_ENABLED, &value); |
| if (ret < 0) |
| pr_err("%s: Fail to execute property\n", __func__); |
| #endif |
| |
| if (fuelgauge->reg_OTP_52 != reg_OTP_52 || fuelgauge->reg_OTP_53 != reg_OTP_53) { |
| #if defined(CONFIG_CHARGER_S2MU205) |
| psy = power_supply_get_by_name("s2mu205-charger"); |
| if (!psy) |
| return -EINVAL; |
| ret = power_supply_set_property(psy, POWER_SUPPLY_PROP_FUELGAUGE_RESET, &value); |
| if (ret < 0) |
| pr_err("%s: Fail to execute property\n", __func__); |
| #endif |
| /* Fuelgauge Write Enable */ |
| s2mu205_update_reg_byte(fuelgauge->i2c, 0x03, IF_EN_MASK, IF_EN_MASK); |
| |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x1F, 0x40); |
| msleep(10); |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x1F, 0x01); |
| msleep(50); |
| |
| /* Fuelgauge Write Enable */ |
| s2mu205_update_reg_byte(fuelgauge->i2c, 0x03, IF_EN_MASK, IF_EN_MASK); |
| |
| s2mu205_read_reg_byte(fuelgauge->i2c, 0x53, ®_OTP_53); |
| s2mu205_read_reg_byte(fuelgauge->i2c, 0x52, ®_OTP_52); |
| |
| dev_err(&fuelgauge->i2c->dev, "1st reset after %s: OTP 52(%02x) 53(%02x) " |
| "current 52(%02x) 53(%02x)\n", __func__, |
| fuelgauge->reg_OTP_52, fuelgauge->reg_OTP_53, reg_OTP_52, reg_OTP_53); |
| |
| if (fuelgauge->reg_OTP_52 != reg_OTP_52 || fuelgauge->reg_OTP_53 != reg_OTP_53) { |
| #if defined(CONFIG_CHARGER_S2MU205) |
| psy = power_supply_get_by_name("s2mu205-charger"); |
| if (!psy) |
| return -EINVAL; |
| ret = power_supply_set_property(psy, POWER_SUPPLY_PROP_FUELGAUGE_RESET, &value); |
| if (ret < 0) |
| pr_err("%s: Fail to execute property\n", __func__); |
| #endif |
| /* Fuelgauge Write Enable */ |
| s2mu205_update_reg_byte(fuelgauge->i2c, 0x03, IF_EN_MASK, IF_EN_MASK); |
| |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x1F, 0x40); |
| msleep(10); |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x1F, 0x01); |
| msleep(50); |
| |
| /* Fuelgauge Write Enable */ |
| s2mu205_update_reg_byte(fuelgauge->i2c, 0x03, IF_EN_MASK, IF_EN_MASK); |
| dev_err(&fuelgauge->i2c->dev, "%s : 2nd reset\n", __func__); |
| } |
| } |
| |
| dev_info(&fuelgauge->i2c->dev, "%s: FG reset\n", __func__); |
| s2mu205_fix_rawsoc_reset_fg(fuelgauge); |
| por_state = 0x00; |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x1F, por_state); |
| |
| #if defined(CONFIG_CHARGER_S2MU205) |
| /* Recover charger status after f.g reset */ |
| if (charging_enabled) { |
| value.intval = SEC_BAT_CHG_MODE_CHARGING; |
| psy = power_supply_get_by_name("s2mu205-charger"); |
| if (!psy) |
| return -EINVAL; |
| ret = power_supply_set_property(psy, POWER_SUPPLY_PROP_CHARGING_ENABLED, &value); |
| if (ret < 0) |
| pr_err("%s: Fail to execute property\n", __func__); |
| } |
| #endif |
| } |
| |
| mutex_lock(&fuelgauge->fg_lock); |
| |
| /* read SOC */ |
| for (i = 0; i < 50; i++) { |
| if (s2mu205_read_reg(fuelgauge->i2c, S2MU205_REG_RSOC, data) < 0) |
| goto err; |
| if (s2mu205_read_reg(fuelgauge->i2c, S2MU205_REG_RSOC, check_data) < 0) |
| goto err; |
| |
| dev_dbg(&fuelgauge->i2c->dev, "[DEBUG]%s: data0 (%d) data1 (%d)\n", __func__, data[0], data[1]); |
| if ((data[0] == check_data[0]) && (data[1] == check_data[1])) |
| break; |
| } |
| |
| mutex_unlock(&fuelgauge->fg_lock); |
| |
| compliment = (data[1] << 8) | (data[0]); |
| |
| /* data[] store 2's compliment format number */ |
| if (compliment & (0x1 << 15)) { |
| /* Negative */ |
| fuelgauge->rsoc = ((~compliment) & 0xFFFF) + 1; |
| fuelgauge->rsoc = (fuelgauge->rsoc * (-10000)) / (0x1 << 14); |
| } else { |
| fuelgauge->rsoc = compliment & 0x7FFF; |
| fuelgauge->rsoc = ((fuelgauge->rsoc * 10000) / (0x1 << 14)); |
| } |
| |
| avg_current = s2mu205_get_avgcurrent(fuelgauge); |
| avg_vbat = s2mu205_get_avgvbat(fuelgauge); |
| vbat = s2mu205_get_vbat(fuelgauge); |
| curr = s2mu205_get_current(fuelgauge); |
| |
| psy = power_supply_get_by_name("battery"); |
| if (!psy) |
| return -EINVAL; |
| |
| s2mu205_read_reg_byte(fuelgauge->i2c, 0x86, &temp); |
| |
| if (!fuelgauge->init_battery_temp && temp != 0) { |
| fuelgauge->temperature = (temp & (0x1 << 7)) ? (-1 * ((~temp & 0xFF) + 1)) : (temp & 0x7F); |
| fuelgauge->temperature *= 10; |
| /* recover default value */ |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x86, 0x0); |
| } else { |
| /* Get temperature from battery driver */ |
| ret = power_supply_get_property(psy, POWER_SUPPLY_PROP_TEMP, &value); |
| if (ret < 0) |
| pr_err("%s: Fail to execute property\n", __func__); |
| fuelgauge->temperature = value.intval; |
| } |
| |
| /* Get UI SOC from battery driver */ |
| ret = power_supply_get_property(psy, POWER_SUPPLY_PROP_CAPACITY, &value); |
| if (ret < 0) |
| pr_err("%s: Fail to execute property\n", __func__); |
| fuelgauge->ui_soc = value.intval; |
| |
| #if (BATCAP_LEARN) || (TEMP_COMPEN) |
| fuelgauge->bat_charging = s2mu205_get_bat_charging(fuelgauge); |
| #endif |
| |
| #if (TEMP_COMPEN) |
| fuelgauge->vm_status = s2mu205_get_vm_status(fuelgauge); |
| fuelgauge->avg_curr = avg_current; |
| s2mu205_temperature_compensation(fuelgauge); |
| |
| dev_info(&fuelgauge->i2c->dev, "%s: current_soc (%d), compen_soc (%d), " |
| "previous_soc (%d), FG_mode(%s)\n", |
| __func__, fuelgauge->rsoc, fuelgauge->soc_r, |
| fuelgauge->info.soc, mode_to_str[fuelgauge->mode]); |
| |
| fuelgauge->info.soc = fuelgauge->soc_r; |
| #else |
| dev_info(&fuelgauge->i2c->dev, "%s: current_soc (%d), previous_soc (%d), FG_mode(%s)\n", |
| __func__, fuelgauge->rsoc, fuelgauge->info.soc, mode_to_str[fuelgauge->mode]); |
| |
| fuelgauge->info.soc = fuelgauge->rsoc; |
| #endif |
| |
| #if defined(CONFIG_CHARGER_S2MU205) |
| psy = power_supply_get_by_name("s2mu205-charger"); |
| if (!psy) |
| return -EINVAL; |
| ret = power_supply_get_property(psy, POWER_SUPPLY_PROP_VOLTAGE_MAX, &value); |
| if (ret < 0) |
| pr_err("%s: Fail to execute property\n", __func__); |
| float_voltage = value.intval; |
| #else |
| float_voltage = 4350; |
| #endif |
| |
| float_voltage = (float_voltage * 996) / 1000; |
| |
| s2mu205_read_reg_byte(fuelgauge->i2c, 0x4A, &fg_mode_reg); |
| |
| dev_info(&fuelgauge->i2c->dev, "%s: UI SOC = %d, is_charging = %d, avg_vbat = %d, " |
| "float_voltage = %d, avg_current = %d, 0x4A = 0x%02x\n", __func__, |
| fuelgauge->ui_soc, fuelgauge->is_charging, avg_vbat, |
| float_voltage, avg_current, fg_mode_reg); |
| |
| if ((fuelgauge->is_charging == true) && |
| ((fuelgauge->ui_soc >= 98) || |
| ((avg_vbat > float_voltage) && |
| (avg_current < check_current_level(fuelgauge))))) { |
| if (fuelgauge->mode == CURRENT_MODE) { /* switch to VOLTAGE_MODE */ |
| fuelgauge->mode = HIGH_SOC_VOLTAGE_MODE; |
| |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x4A, 0xFF); |
| s2mu205_update_reg_byte(fuelgauge->i2c, 0x4B, 0x70, 0x70); |
| |
| dev_info(&fuelgauge->i2c->dev, "%s: FG is in high soc voltage mode\n", __func__); |
| } |
| } else if (avg_current < -50 || avg_current >= check_current_level(fuelgauge)) { |
| if (fuelgauge->mode == HIGH_SOC_VOLTAGE_MODE) { |
| fuelgauge->mode = CURRENT_MODE; |
| |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x4A, 0x10); |
| s2mu205_update_reg_byte(fuelgauge->i2c, 0x4B, 0x00, 0x70); |
| |
| dev_info(&fuelgauge->i2c->dev, "%s: FG is in current mode\n", __func__); |
| } |
| } |
| |
| #if (BATCAP_LEARN) |
| fuelgauge->capcc = s2mu205_get_cap_cc(fuelgauge); |
| fuelgauge->batcap_ocv = s2mu205_get_batcap_ocv(fuelgauge); // CC mode capacity |
| fuelgauge->cycle = s2mu205_get_cycle(fuelgauge); |
| BATCAP_L_VBAT = (BAT_L_CON[1] == 0) ? 4200:4100; |
| |
| if (fuelgauge->temperature >= 200) { |
| if (fuelgauge->learn_start == false) { |
| if ((fuelgauge->rsoc < 1000) && (fuelgauge->cycle >= BAT_L_CON[0])) |
| fuelgauge->learn_start = true; |
| } else { |
| if ((fuelgauge->cond1_ok == false) && (fuelgauge->bat_charging == false)) |
| goto batcap_learn_init; |
| |
| if (fuelgauge->cond1_ok == false) { |
| if (fuelgauge->c1_count >= BAT_L_CON[2]) { |
| fuelgauge->cond1_ok = true; |
| fuelgauge->c1_count = 0; |
| } else { |
| if ((vbat >= BATCAP_L_VBAT) && (avg_current < BAT_L_CON[4]) && |
| (fuelgauge->rsoc >= 9700)) { |
| fuelgauge->c1_count++; |
| } else { |
| fuelgauge->c1_count = 0; |
| } |
| } |
| } else { |
| if (fuelgauge->c2_count >= BAT_L_CON[3]) { |
| s2mu205_batcap_learning(fuelgauge); |
| goto batcap_learn_init; |
| } else { |
| if ((vbat >= (BATCAP_L_VBAT - 100)) && (avg_current > -30) && |
| (avg_current < 30) && (fuelgauge->rsoc >= 9800)) { |
| fuelgauge->c2_count++; |
| } else { |
| fuelgauge->c2_count = 0; |
| |
| if (avg_current <= -30) |
| goto batcap_learn_init; |
| } |
| } |
| } |
| } |
| } else { |
| batcap_learn_init: |
| fuelgauge->learn_start = false; |
| fuelgauge->cond1_ok = false; |
| fuelgauge->c1_count = 0; |
| fuelgauge->c2_count = 0; |
| } |
| #endif |
| |
| #if (TEMP_COMPEN) && (BATCAP_LEARN) |
| fuelgauge->soh = s2mu205_get_soh(fuelgauge); |
| fuelgauge->capcc = s2mu205_get_cap_cc(fuelgauge); |
| fuelgauge->fcc = s2mu205_get_fullcharge_cap(fuelgauge); |
| fuelgauge->rmc = s2mu205_get_remaining_cap(fuelgauge); |
| |
| pr_info("%s: SOC_M = %d, Chg_stat = %d, VM = %d, avbVBAT = %d, avgCURR = %d, avgTEMP = %d, " |
| "SOCni = %d, SOC0i = %d, SOCr = %d, SOC_R = %d, " |
| "Learning_start = %d, C1_count = %d/%d, C2_count = %d/%d, " |
| "BATCAP_OCV_new = %d, SOH = %d, CAP_CC = %d, FCC = %d, RM = %d\n", |
| __func__, |
| fuelgauge->rsoc, fuelgauge->bat_charging, fuelgauge->vm_status, avg_vbat, avg_current, fuelgauge->temperature, |
| fuelgauge->socni, fuelgauge->soc0i, fuelgauge->comp_socr, fuelgauge->soc_r, |
| fuelgauge->learn_start, fuelgauge->c1_count, BAT_L_CON[2], fuelgauge->c2_count, BAT_L_CON[3], |
| fuelgauge->batcap_ocv_fin, fuelgauge->soh, fuelgauge->capcc, fuelgauge->fcc, fuelgauge->rmc); |
| #endif |
| |
| /* Low voltage W/A, make 0% */ |
| if ((avg_vbat < 3450) && (avg_current < -50) && (fuelgauge->info.soc > 100)) { |
| if (fuelgauge->temperature > fuelgauge->low_temp_limit) { |
| dev_info(&fuelgauge->i2c->dev, "%s: Low voltage WA. Make rawsoc 0\n", __func__); |
| |
| s2mu205_update_reg_byte(fuelgauge->i2c, 0x25, 0x04, 0x0F); |
| |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x24, 0x01); |
| /* Dumpdone. Re-calculate SOC */ |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x1E, 0x0F); |
| msleep(300); |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x24, 0x00); |
| |
| /* Make report SOC 0% */ |
| fuelgauge->info.soc = 0; |
| #if (TEMP_COMPEN) |
| fuelgauge->soc_r = 0; |
| #endif |
| } else { |
| dev_info(&fuelgauge->i2c->dev, "%s: Low voltage WA. Make UI SOC 0\n", __func__); |
| |
| /* Make report SOC 0% */ |
| fuelgauge->info.soc = 0; |
| #if (TEMP_COMPEN) |
| fuelgauge->soc_r = 0; |
| #endif |
| } |
| } |
| |
| #if (TEMP_COMPEN) |
| /* Low temperature W/A, Maintain UI SOC if battery is relaxing */ |
| if (((fuelgauge->temperature < fuelgauge->low_temp_limit) && |
| (fuelgauge->soc_r == 0) && (fuelgauge->ui_soc > 10)) && |
| (((avg_current > -60) && (avg_current < 50)) || ((curr > -100) && (curr < 50)))) { |
| fuelgauge->soc_r = fuelgauge->ui_soc * 100; |
| fuelgauge->info.soc = fuelgauge->soc_r; |
| fuelgauge->init_start = 1; |
| |
| dev_info(&fuelgauge->i2c->dev, |
| "%s: Maintain UI SOC if battery is relaxing SOC_R = %d, info.soc = %d\n", |
| __func__, fuelgauge->soc_r, fuelgauge->info.soc); |
| } |
| #endif |
| |
| /* S2MU205 FG debug */ |
| s2mu205_fg_test_read(fuelgauge->i2c); |
| |
| return min(fuelgauge->info.soc, 10000); |
| |
| err: |
| mutex_unlock(&fuelgauge->fg_lock); |
| return -EINVAL; |
| |
| } |
| |
| static int s2mu205_get_current(struct s2mu205_fuelgauge_data *fuelgauge) |
| { |
| u8 data[2]; |
| u16 compliment; |
| int curr = 0; |
| |
| if (s2mu205_read_reg(fuelgauge->i2c, S2MU205_REG_RCUR_CC, data) < 0) |
| return -EINVAL; |
| compliment = (data[1] << 8) | (data[0]); |
| dev_dbg(&fuelgauge->i2c->dev, "%s: rCUR_CC(0x%4x)\n", __func__, compliment); |
| |
| if (compliment & (0x1 << 15)) { /* Charging */ |
| curr = ((~compliment) & 0xFFFF) + 1; |
| curr = (curr * 1000) >> 12; |
| } else { /* dischaging */ |
| curr = compliment & 0x7FFF; |
| curr = (curr * (-1000)) >> 12; |
| } |
| |
| dev_info(&fuelgauge->i2c->dev, "%s: current (%d)mA\n", __func__, curr); |
| |
| return curr; |
| } |
| |
| static int s2mu205_get_ocv(struct s2mu205_fuelgauge_data *fuelgauge) |
| { |
| int *soc_arr; |
| int *ocv_arr; |
| |
| int soc = fuelgauge->info.soc; |
| int ocv = 0; |
| |
| int high_index = TABLE_SIZE - 1; |
| int low_index = 0; |
| int mid_index = 0; |
| |
| #if defined(CONFIG_BATTERY_AGE_FORECAST) |
| soc_arr = fuelgauge->age_data_info[fuelgauge->fg_age_step].soc_arr_val; |
| ocv_arr = fuelgauge->age_data_info[fuelgauge->fg_age_step].ocv_arr_val; |
| #else |
| soc_arr = fuelgauge->info.soc_arr_val; |
| ocv_arr = fuelgauge->info.ocv_arr_val; |
| #endif |
| |
| dev_err(&fuelgauge->i2c->dev, |
| "%s: soc (%d) soc_arr[TABLE_SIZE-1] (%d) ocv_arr[TABLE_SIZE-1) (%d)\n", |
| __func__, soc, soc_arr[TABLE_SIZE-1], ocv_arr[TABLE_SIZE-1]); |
| if (soc <= soc_arr[TABLE_SIZE - 1]) { |
| ocv = ocv_arr[TABLE_SIZE - 1]; |
| goto ocv_soc_mapping; |
| } else if (soc >= soc_arr[0]) { |
| ocv = ocv_arr[0]; |
| goto ocv_soc_mapping; |
| } |
| while (low_index <= high_index) { |
| mid_index = (low_index + high_index) >> 1; |
| if (soc_arr[mid_index] > soc) |
| low_index = mid_index + 1; |
| else if (soc_arr[mid_index] < soc) |
| high_index = mid_index - 1; |
| else { |
| ocv = ocv_arr[mid_index]; |
| goto ocv_soc_mapping; |
| } |
| } |
| ocv = ocv_arr[high_index]; |
| ocv += ((ocv_arr[low_index] - ocv_arr[high_index]) * |
| (soc - soc_arr[high_index])) / |
| (soc_arr[low_index] - soc_arr[high_index]); |
| |
| ocv_soc_mapping: |
| dev_info(&fuelgauge->i2c->dev, "%s: soc (%d), ocv (%d)\n", __func__, soc, ocv); |
| return ocv; |
| } |
| |
| static int s2mu205_get_avgcurrent(struct s2mu205_fuelgauge_data *fuelgauge) |
| { |
| u8 data[2]; |
| u16 compliment; |
| int curr = 0; |
| mutex_lock(&fuelgauge->fg_lock); |
| |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, S2MU205_REG_MONOUT_SEL, 0x17); |
| |
| if (s2mu205_read_reg(fuelgauge->i2c, S2MU205_REG_MONOUT, data) < 0) |
| goto err; |
| compliment = (data[1] << 8) | (data[0]); |
| dev_dbg(&fuelgauge->i2c->dev, "%s: MONOUT(0x%4x)\n", __func__, compliment); |
| |
| if (compliment & (0x1 << 15)) { /* Charging */ |
| curr = ((~compliment) & 0xFFFF) + 1; |
| curr = (curr * 1000) >> 12; |
| } else { /* dischaging */ |
| curr = compliment & 0x7FFF; |
| curr = (curr * (-1000)) >> 12; |
| } |
| |
| mutex_unlock(&fuelgauge->fg_lock); |
| |
| dev_info(&fuelgauge->i2c->dev, "%s: avg current (%d)mA\n", __func__, curr); |
| |
| return curr; |
| |
| err: |
| mutex_unlock(&fuelgauge->fg_lock); |
| return -EINVAL; |
| } |
| |
| static int s2mu205_maintain_avgcurrent( |
| struct s2mu205_fuelgauge_data *fuelgauge) |
| { |
| static int cnt; |
| int vcell = 0; |
| int curr = 0; |
| |
| curr = s2mu205_get_avgcurrent(fuelgauge); |
| |
| vcell = s2mu205_get_vbat(fuelgauge); |
| if ((cnt < 10) && (curr < 0) && (fuelgauge->is_charging) && |
| (vcell < 3500)) { |
| curr = 1; |
| cnt++; |
| dev_info(&fuelgauge->i2c->dev, "%s: vcell (%d)mV, modified avg current (%d)mA\n", |
| __func__, vcell, curr); |
| } |
| |
| return curr; |
| } |
| |
| static int s2mu205_get_vbat(struct s2mu205_fuelgauge_data *fuelgauge) |
| { |
| u8 data[2]; |
| u32 vbat = 0; |
| |
| if (s2mu205_read_reg(fuelgauge->i2c, S2MU205_REG_RVBAT, data) < 0) |
| return -EINVAL; |
| |
| dev_dbg(&fuelgauge->i2c->dev, "%s: data0 (%d) data1 (%d)\n", __func__, data[0], data[1]); |
| vbat = ((data[0] + (data[1] << 8)) * 1000) >> 13; |
| |
| dev_info(&fuelgauge->i2c->dev, "%s: vbat (%d)\n", __func__, vbat); |
| |
| return vbat; |
| } |
| |
| static int s2mu205_get_avgvbat(struct s2mu205_fuelgauge_data *fuelgauge) |
| { |
| u8 data[2]; |
| u16 compliment, avg_vbat; |
| |
| mutex_lock(&fuelgauge->fg_lock); |
| |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, S2MU205_REG_MONOUT_SEL, 0x16); |
| |
| if (s2mu205_read_reg(fuelgauge->i2c, S2MU205_REG_MONOUT, data) < 0) |
| goto err; |
| |
| compliment = (data[1] << 8) | (data[0]); |
| avg_vbat = (compliment * 1000) >> 12; |
| |
| mutex_unlock(&fuelgauge->fg_lock); |
| |
| dev_info(&fuelgauge->i2c->dev, "%s: avgvbat (%d)\n", __func__, avg_vbat); |
| |
| return avg_vbat; |
| |
| err: |
| mutex_unlock(&fuelgauge->fg_lock); |
| return -EINVAL; |
| } |
| |
| static void s2mu205_fuelalert_init(struct s2mu205_fuelgauge_data *fuelgauge) |
| { |
| u8 data; |
| fuelgauge->is_fuel_alerted = false; |
| |
| /* VBAT Threshold setting: 3.55V */ |
| data = (fuelgauge->pdata->fuel_alert_soc << 4) | 0x0F; |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, S2MU205_REG_ALERT_LVL, data); |
| |
| /* VBAT, SOC IRQ enable */ |
| s2mu205_update_reg_byte(fuelgauge->i2c, S2MU205_REG_IRQ_M, 0x00, 0x03); |
| |
| pr_info("%s: irq_reg(%02x) irq(%d)\n", |
| __func__, data, fuelgauge->pdata->fg_irq); |
| } |
| |
| static void s2mu205_fg_isr_work(struct work_struct *work) |
| { |
| struct s2mu205_fuelgauge_data *fuelgauge = |
| container_of(work, struct s2mu205_fuelgauge_data, isr_work.work); |
| u8 fg_alert_status = 0; |
| |
| s2mu205_read_reg_byte(fuelgauge->i2c, S2MU205_REG_STATUS, &fg_alert_status); |
| dev_info(&fuelgauge->i2c->dev, "%s : fg_alert_status(0x%x)\n", |
| __func__, fg_alert_status); |
| |
| fg_alert_status &= 0x03; |
| if (fg_alert_status & 0x01) |
| pr_info("%s : Battery Level(SOC) is very Low!\n", __func__); |
| |
| if (fg_alert_status & 0x02) { |
| int voltage = s2mu205_get_vbat(fuelgauge); |
| |
| pr_info("%s : Battery Votage is very Low! (%dmV)\n", |
| __func__, voltage); |
| } |
| |
| if (!fg_alert_status) { |
| fuelgauge->is_fuel_alerted = false; |
| pr_info("%s : SOC or Voltage is Good!\n", __func__); |
| wake_unlock(&fuelgauge->fuel_alert_wake_lock); |
| } |
| } |
| |
| static irqreturn_t s2mu205_fg_irq_thread(int irq, void *irq_data) |
| { |
| struct s2mu205_fuelgauge_data *fuelgauge = irq_data; |
| u8 fg_irq = 0; |
| |
| s2mu205_read_reg_byte(fuelgauge->i2c, S2MU205_REG_IRQ, &fg_irq); |
| dev_info(&fuelgauge->i2c->dev, "%s: fg_irq(0x%x)\n", |
| __func__, fg_irq); |
| |
| if (fuelgauge->is_fuel_alerted) { |
| return IRQ_HANDLED; |
| } else { |
| wake_lock(&fuelgauge->fuel_alert_wake_lock); |
| fuelgauge->is_fuel_alerted = true; |
| schedule_delayed_work(&fuelgauge->isr_work, 0); |
| } |
| |
| return IRQ_HANDLED; |
| } |
| |
| #if defined(CONFIG_BATTERY_AGE_FORECAST) |
| static int s2mu205_fg_aging_check( |
| struct s2mu205_fuelgauge_data *fuelgauge, int step) |
| { |
| u8 batcap0 = 0, batcap1 = 0, batcap2 = 0, batcap3 = 0; |
| u8 por_state = 0; |
| union power_supply_propval value; |
| int charging_enabled = false; |
| |
| fuelgauge->fg_age_step = step; |
| |
| s2mu205_read_reg_byte(fuelgauge->i2c, 0x88, &batcap0); |
| s2mu205_read_reg_byte(fuelgauge->i2c, 0x89, &batcap1); |
| s2mu205_read_reg_byte(fuelgauge->i2c, 0x10, &batcap2); |
| s2mu205_read_reg_byte(fuelgauge->i2c, 0x11, &batcap3); |
| |
| pr_info("%s: [Long life] orig. batcap : %02x, %02x, %02x, %02x , fg_age_step data : %02x, %02x, %02x, %02x \n", |
| __func__, batcap0, batcap1, batcap2, batcap3, |
| fuelgauge->age_data_info[fuelgauge->fg_age_step].batcap[0], |
| fuelgauge->age_data_info[fuelgauge->fg_age_step].batcap[1], |
| fuelgauge->age_data_info[fuelgauge->fg_age_step].batcap[2], |
| fuelgauge->age_data_info[fuelgauge->fg_age_step].batcap[3]); |
| |
| if ((batcap0 != fuelgauge->age_data_info[fuelgauge->fg_age_step].batcap[0]) || |
| (batcap1 != fuelgauge->age_data_info[fuelgauge->fg_age_step].batcap[1]) || |
| (batcap2 != fuelgauge->age_data_info[fuelgauge->fg_age_step].batcap[2]) || |
| (batcap3 != fuelgauge->age_data_info[fuelgauge->fg_age_step].batcap[3])) { |
| |
| pr_info("%s: [Long life] reset gauge for age forecast , step[%d] \n", __func__, fuelgauge->fg_age_step); |
| |
| fuelgauge->age_reset_status = 1; |
| por_state |= 0x10; |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x1F, por_state); |
| |
| /* check charging enable */ |
| psy_do_property("s2mu205-charger", get, POWER_SUPPLY_PROP_CHARGING_ENABLED, value); |
| charging_enabled = value.intval; |
| |
| if (charging_enabled == true) { |
| pr_info("%s: [Long life] disable charger for reset gauge age forecast \n", |
| __func__); |
| value.intval = SEC_BAT_CHG_MODE_CHARGING_OFF; |
| psy_do_property("s2mu205-charger", set, POWER_SUPPLY_PROP_CHARGING_ENABLED, value); |
| } |
| |
| s2mu205_reset_fg(fuelgauge); |
| #if (TEMP_COMPEN) |
| fuelgauge->init_start = 1; |
| #endif |
| |
| if (charging_enabled == true) { |
| psy_do_property("battery", get, POWER_SUPPLY_PROP_STATUS, value); |
| charging_enabled = value.intval; |
| |
| if (charging_enabled == 1) { /* POWER_SUPPLY_STATUS_CHARGING 1 */ |
| pr_info("%s: [Long life] enable charger for reset gauge age forecast \n", |
| __func__); |
| value.intval = SEC_BAT_CHG_MODE_CHARGING; |
| psy_do_property("s2mu205-charger", |
| set, POWER_SUPPLY_PROP_CHARGING_ENABLED, value); |
| } |
| } |
| |
| por_state &= ~0x10; |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x1F, por_state); |
| fuelgauge->age_reset_status = 0; |
| |
| return 1; |
| } |
| return 0; |
| } |
| #endif |
| |
| /* capacity is 0.1% unit */ |
| static void s2mu205_fg_get_scaled_capacity( |
| struct s2mu205_fuelgauge_data *fuelgauge, |
| union power_supply_propval *val) |
| { |
| int rawsoc = val->intval; |
| |
| val->intval = (val->intval < fuelgauge->pdata->capacity_min) ? |
| 0 : ((val->intval - fuelgauge->pdata->capacity_min) * 1000 / |
| (fuelgauge->capacity_max - fuelgauge->pdata->capacity_min)); |
| |
| dev_info(&fuelgauge->i2c->dev, |
| "%s: capacity_max(%d) scaled capacity(%d.%d), raw_soc(%d.%d)\n", |
| __func__, fuelgauge->capacity_max, |
| val->intval/10, val->intval%10, rawsoc/10, rawsoc%10); |
| } |
| |
| /* capacity is integer */ |
| static void s2mu205_fg_get_atomic_capacity( |
| struct s2mu205_fuelgauge_data *fuelgauge, |
| union power_supply_propval *val) |
| { |
| if (fuelgauge->pdata->capacity_calculation_type & |
| SEC_FUELGAUGE_CAPACITY_TYPE_ATOMIC) { |
| if (fuelgauge->capacity_old < val->intval) |
| val->intval = fuelgauge->capacity_old + 1; |
| else if (fuelgauge->capacity_old > val->intval) |
| val->intval = fuelgauge->capacity_old - 1; |
| } |
| |
| /* keep SOC stable in abnormal status */ |
| if (fuelgauge->pdata->capacity_calculation_type & |
| SEC_FUELGAUGE_CAPACITY_TYPE_SKIP_ABNORMAL) { |
| if (!fuelgauge->is_charging && |
| fuelgauge->capacity_old < val->intval) { |
| dev_err(&fuelgauge->i2c->dev, |
| "%s: capacity (old %d : new %d)\n", |
| __func__, fuelgauge->capacity_old, val->intval); |
| val->intval = fuelgauge->capacity_old; |
| } |
| } |
| |
| /* updated old capacity */ |
| fuelgauge->capacity_old = val->intval; |
| } |
| |
| static int s2mu205_fg_check_capacity_max( |
| struct s2mu205_fuelgauge_data *fuelgauge, int capacity_max) |
| { |
| int new_capacity_max = capacity_max; |
| |
| if (new_capacity_max < (fuelgauge->pdata->capacity_max - |
| fuelgauge->pdata->capacity_max_margin - 10)) { |
| new_capacity_max = |
| (fuelgauge->pdata->capacity_max - |
| fuelgauge->pdata->capacity_max_margin); |
| |
| dev_info(&fuelgauge->i2c->dev, "%s: set capacity max(%d --> %d)\n", |
| __func__, capacity_max, new_capacity_max); |
| } else if (new_capacity_max > (fuelgauge->pdata->capacity_max + |
| fuelgauge->pdata->capacity_max_margin)) { |
| new_capacity_max = |
| (fuelgauge->pdata->capacity_max + |
| fuelgauge->pdata->capacity_max_margin); |
| |
| dev_info(&fuelgauge->i2c->dev, "%s: set capacity max(%d --> %d)\n", |
| __func__, capacity_max, new_capacity_max); |
| } |
| |
| return new_capacity_max; |
| } |
| |
| static int s2mu205_fg_calculate_dynamic_scale( |
| struct s2mu205_fuelgauge_data *fuelgauge, int capacity) |
| { |
| union power_supply_propval raw_soc_val; |
| raw_soc_val.intval = s2mu205_get_rawsoc(fuelgauge) / 10; |
| |
| if (raw_soc_val.intval < |
| fuelgauge->pdata->capacity_max - |
| fuelgauge->pdata->capacity_max_margin) { |
| pr_info("%s: raw soc(%d) is very low, skip routine\n", |
| __func__, raw_soc_val.intval); |
| } else { |
| fuelgauge->capacity_max = |
| (raw_soc_val.intval * 100 / (capacity + 1)); |
| fuelgauge->capacity_old = capacity; |
| |
| fuelgauge->capacity_max = |
| s2mu205_fg_check_capacity_max(fuelgauge, |
| fuelgauge->capacity_max); |
| |
| pr_info("%s: %d is used for capacity_max, capacity(%d)\n", |
| __func__, fuelgauge->capacity_max, capacity); |
| } |
| |
| return fuelgauge->capacity_max; |
| } |
| |
| static int s2mu205_fg_get_property(struct power_supply *psy, |
| enum power_supply_property psp, |
| union power_supply_propval *val) |
| { |
| struct s2mu205_fuelgauge_data *fuelgauge = |
| power_supply_get_drvdata(psy); |
| |
| switch (psp) { |
| case POWER_SUPPLY_PROP_STATUS: |
| case POWER_SUPPLY_PROP_CHARGE_FULL: |
| return -ENODATA; |
| case POWER_SUPPLY_PROP_CHARGE_COUNTER: |
| val->intval = fuelgauge->pdata->capacity_full * fuelgauge->raw_capacity; |
| break; |
| case POWER_SUPPLY_PROP_ENERGY_NOW: |
| switch (val->intval) { |
| case SEC_BATTERY_CAPACITY_DESIGNED: |
| val->intval = fuelgauge->pdata->capacity_full; |
| break; |
| case SEC_BATTERY_CAPACITY_ABSOLUTE: |
| val->intval = 0; |
| break; |
| case SEC_BATTERY_CAPACITY_TEMPERARY: |
| val->intval = 0; |
| break; |
| case SEC_BATTERY_CAPACITY_CURRENT: |
| val->intval = 0; |
| break; |
| case SEC_BATTERY_CAPACITY_AGEDCELL: |
| val->intval = 0; |
| break; |
| case SEC_BATTERY_CAPACITY_CYCLE: |
| val->intval = 0; |
| break; |
| case SEC_BATTERY_CAPACITY_FULL: |
| val->intval = fuelgauge->pdata->capacity_full; |
| break; |
| } |
| break; |
| /* Cell voltage (VCELL, mV) */ |
| case POWER_SUPPLY_PROP_VOLTAGE_NOW: |
| val->intval = s2mu205_get_vbat(fuelgauge); |
| break; |
| /* Additional Voltage Information (mV) */ |
| case POWER_SUPPLY_PROP_VOLTAGE_AVG: |
| switch (val->intval) { |
| case SEC_BATTERY_VOLTAGE_AVERAGE: |
| val->intval = s2mu205_get_avgvbat(fuelgauge); |
| break; |
| case SEC_BATTERY_VOLTAGE_OCV: |
| val->intval = s2mu205_get_ocv(fuelgauge); |
| break; |
| } |
| break; |
| /* Current (mA) */ |
| case POWER_SUPPLY_PROP_CURRENT_NOW: |
| if (val->intval == SEC_BATTERY_CURRENT_UA) |
| val->intval = s2mu205_get_current(fuelgauge) * 1000; |
| else |
| val->intval = s2mu205_get_current(fuelgauge); |
| break; |
| /* Average Current (mA) */ |
| case POWER_SUPPLY_PROP_CURRENT_AVG: |
| if (val->intval == SEC_BATTERY_CURRENT_UA) |
| val->intval = s2mu205_maintain_avgcurrent(fuelgauge) * 1000; |
| else |
| val->intval = s2mu205_maintain_avgcurrent(fuelgauge); |
| break; |
| case POWER_SUPPLY_PROP_CAPACITY: |
| if (val->intval == SEC_FUELGAUGE_CAPACITY_TYPE_RAW) { |
| val->intval = s2mu205_get_rawsoc(fuelgauge); |
| } else if (val->intval == SEC_FUELGAUGE_CAPACITY_TYPE_DYNAMIC_SCALE) { |
| val->intval = fuelgauge->raw_capacity; |
| } |
| else { |
| val->intval = s2mu205_get_rawsoc(fuelgauge) / 10; |
| |
| if (fuelgauge->pdata->capacity_calculation_type & |
| (SEC_FUELGAUGE_CAPACITY_TYPE_SCALE | |
| SEC_FUELGAUGE_CAPACITY_TYPE_DYNAMIC_SCALE)) |
| s2mu205_fg_get_scaled_capacity(fuelgauge, val); |
| |
| /* capacity should be between 0% and 100% |
| * (0.1% degree) |
| */ |
| if (val->intval > 1000) |
| val->intval = 1000; |
| if (val->intval < 0) |
| val->intval = 0; |
| fuelgauge->raw_capacity = val->intval; |
| |
| /* get only integer part */ |
| val->intval /= 10; |
| |
| /* check whether doing the wake_unlock */ |
| if ((val->intval > fuelgauge->pdata->fuel_alert_soc) && |
| fuelgauge->is_fuel_alerted) { |
| wake_unlock(&fuelgauge->fuel_alert_wake_lock); |
| s2mu205_fuelalert_init(fuelgauge); |
| } |
| |
| /* (Only for atomic capacity) |
| * In initial time, capacity_old is 0. |
| * and in resume from sleep, |
| * capacity_old is too different from actual soc. |
| * should update capacity_old |
| * by val->intval in booting or resume. |
| */ |
| if (fuelgauge->initial_update_of_soc) { |
| /* updated old capacity */ |
| fuelgauge->capacity_old = val->intval; |
| fuelgauge->initial_update_of_soc = false; |
| break; |
| } |
| |
| if (fuelgauge->sleep_initial_update_of_soc) { |
| /* updated old capacity in case of resume */ |
| if (fuelgauge->is_charging) { |
| fuelgauge->capacity_old = val->intval; |
| fuelgauge->sleep_initial_update_of_soc = false; |
| break; |
| } else if ((!fuelgauge->is_charging) && |
| (fuelgauge->capacity_old >= val->intval)) { |
| fuelgauge->capacity_old = val->intval; |
| fuelgauge->sleep_initial_update_of_soc = false; |
| break; |
| } |
| } |
| |
| if (fuelgauge->pdata->capacity_calculation_type & |
| (SEC_FUELGAUGE_CAPACITY_TYPE_ATOMIC | |
| SEC_FUELGAUGE_CAPACITY_TYPE_SKIP_ABNORMAL)) |
| s2mu205_fg_get_atomic_capacity(fuelgauge, val); |
| } |
| break; |
| /* Battery Temperature */ |
| case POWER_SUPPLY_PROP_TEMP: |
| /* Target Temperature */ |
| case POWER_SUPPLY_PROP_TEMP_AMBIENT: |
| val->intval = s2mu205_get_temperature(fuelgauge); |
| break; |
| case POWER_SUPPLY_PROP_ENERGY_FULL: |
| #if (BATCAP_LEARN) |
| fuelgauge->soh = s2mu205_get_soh(fuelgauge); |
| val->intval = fuelgauge->soh; |
| #endif |
| break; |
| case POWER_SUPPLY_PROP_ENERGY_FULL_DESIGN: |
| val->intval = fuelgauge->capacity_max; |
| break; |
| case POWER_SUPPLY_PROP_SCOPE: |
| val->intval = fuelgauge->mode; |
| break; |
| case POWER_SUPPLY_PROP_SOH: |
| #if (BATCAP_LEARN) |
| fuelgauge->soh = s2mu205_get_soh(fuelgauge); |
| val->intval = fuelgauge->soh; |
| #else |
| /* If battery capacity learning is not enabled, |
| * return SOH is 100% |
| */ |
| val->intval = 100; |
| #endif |
| break; |
| default: |
| return -EINVAL; |
| } |
| |
| return 0; |
| } |
| |
| static int s2mu205_fg_set_property(struct power_supply *psy, |
| enum power_supply_property psp, |
| const union power_supply_propval *val) |
| { |
| struct s2mu205_fuelgauge_data *fuelgauge = |
| power_supply_get_drvdata(psy); |
| enum power_supply_ext_property ext_psp = psp; |
| u8 temp = 0; |
| |
| switch (psp) { |
| case POWER_SUPPLY_PROP_STATUS: |
| #if defined(CONFIG_BATTERY_AGE_FORECAST) |
| if (val->intval == POWER_SUPPLY_STATUS_FULL) |
| s2mu205_fg_aging_check(fuelgauge, fuelgauge->change_step); |
| #endif |
| break; |
| case POWER_SUPPLY_PROP_CHARGE_FULL: |
| if (fuelgauge->pdata->capacity_calculation_type & |
| SEC_FUELGAUGE_CAPACITY_TYPE_DYNAMIC_SCALE) { |
| s2mu205_fg_calculate_dynamic_scale(fuelgauge, val->intval); |
| } |
| break; |
| case POWER_SUPPLY_PROP_ONLINE: |
| fuelgauge->cable_type = val->intval; |
| break; |
| case POWER_SUPPLY_PROP_CHARGING_ENABLED: |
| if (val->intval) |
| fuelgauge->is_charging = true; |
| else |
| fuelgauge->is_charging = false; |
| break; |
| case POWER_SUPPLY_PROP_CAPACITY: |
| if (val->intval == SEC_FUELGAUGE_CAPACITY_TYPE_RESET) { |
| s2mu205_restart_gauging(fuelgauge); |
| fuelgauge->initial_update_of_soc = true; |
| } |
| break; |
| case POWER_SUPPLY_PROP_TEMP: |
| case POWER_SUPPLY_PROP_TEMP_AMBIENT: |
| s2mu205_set_temperature(fuelgauge, val->intval); |
| fuelgauge->init_battery_temp = true; |
| break; |
| case POWER_SUPPLY_PROP_ENERGY_NOW: |
| s2mu205_fg_reset_capacity_by_jig_connection(fuelgauge); |
| break; |
| case POWER_SUPPLY_PROP_ENERGY_FULL_DESIGN: |
| dev_info(&fuelgauge->i2c->dev, |
| "%s: capacity_max changed, %d -> %d\n", |
| __func__, fuelgauge->capacity_max, val->intval); |
| fuelgauge->capacity_max = s2mu205_fg_check_capacity_max(fuelgauge, val->intval); |
| fuelgauge->initial_update_of_soc = true; |
| break; |
| case POWER_SUPPLY_PROP_CHARGE_EMPTY: |
| break; |
| case POWER_SUPPLY_PROP_ENERGY_AVG: |
| break; |
| case POWER_SUPPLY_PROP_CURRENT_FULL: |
| fuelgauge->topoff_current = val->intval; |
| break; |
| case POWER_SUPPLY_PROP_MAX ... POWER_SUPPLY_EXT_PROP_MAX: |
| switch (ext_psp) { |
| case POWER_SUPPLY_EXT_PROP_INBAT_VOLTAGE_FGSRC_SWITCHING: |
| if ((val->intval == SEC_BAT_INBAT_FGSRC_SWITCHING_ON) || |
| (val->intval == SEC_BAT_FGSRC_SWITCHING_ON)) { |
| /* Get Battery voltage (by I2C control) */ |
| s2mu205_update_reg_byte(fuelgauge->i2c, 0x25, 0x10, 0x30); |
| msleep(1000); |
| s2mu205_read_reg_byte(fuelgauge->i2c, 0x25, &temp); |
| pr_info("%s: SW Vbat: fgsrc_switching_on: REG25:0x%02x, 0x25[5:4]=0x%x\n", __func__, temp, (temp & 0x30) >> 4); |
| if (val->intval == SEC_BAT_INBAT_FGSRC_SWITCHING_ON) |
| s2mu205_restart_gauging(fuelgauge); |
| s2mu205_fg_reset_capacity_by_jig_connection(fuelgauge); |
| s2mu205_fg_test_read(fuelgauge->i2c); |
| } else if ((val->intval == SEC_BAT_INBAT_FGSRC_SWITCHING_OFF) || |
| (val->intval == SEC_BAT_FGSRC_SWITCHING_OFF)) { |
| s2mu205_update_reg_byte(fuelgauge->i2c, 0x25, 0x30, 0x30); |
| msleep(1000); |
| s2mu205_read_reg_byte(fuelgauge->i2c, 0x25, &temp); |
| pr_info("%s: SW Vsys: fgsrc_switching_off: REG25:0x%02x, 0x25[5:4]=0x%x\n", __func__, temp, (temp & 0x30) >> 4); |
| if (val->intval == SEC_BAT_INBAT_FGSRC_SWITCHING_OFF) |
| s2mu205_restart_gauging(fuelgauge); |
| s2mu205_fg_test_read(fuelgauge->i2c); |
| } |
| break; |
| case POWER_SUPPLY_EXT_PROP_FUELGAUGE_FACTORY: |
| pr_info("%s:[DEBUG_FAC] fuelgauge\n", __func__); |
| s2mu205_update_reg_byte(fuelgauge->i2c, 0x25, 0x30, 0x30); |
| s2mu205_fg_reset_capacity_by_jig_connection(fuelgauge); |
| break; |
| #if defined(CONFIG_BATTERY_AGE_FORECAST) |
| case POWER_SUPPLY_EXT_PROP_UPDATE_BATTERY_DATA: |
| fuelgauge->change_step = val->intval; |
| break; |
| #endif |
| default: |
| return -EINVAL; |
| } |
| break; |
| default: |
| return -EINVAL; |
| } |
| |
| return 0; |
| } |
| |
| static void s2mu205_init_regs(struct s2mu205_fuelgauge_data *fuelgauge) |
| { |
| u8 temp = 0; |
| pr_info("%s: s2mu205 fuelgauge initialize\n", __func__); |
| |
| /* Save register values for surge check */ |
| s2mu205_read_reg_byte(fuelgauge->i2c, 0x53, &temp); |
| fuelgauge->reg_OTP_53 = temp; |
| s2mu205_read_reg_byte(fuelgauge->i2c, 0x52, &temp); |
| fuelgauge->reg_OTP_52 = temp; |
| |
| /* Disable VM3_flag_EN */ |
| s2mu205_update_reg_byte(fuelgauge->i2c, S2MU205_REG_VM, 0x00, 0x04); |
| } |
| |
| #ifdef CONFIG_OF |
| static int s2mu205_fuelgauge_parse_dt(struct s2mu205_fuelgauge_data *fuelgauge) |
| { |
| struct device_node *np = of_find_node_by_name(NULL, "s2mu205-fuelgauge"); |
| int ret; |
| #if defined(CONFIG_BATTERY_AGE_FORECAST) |
| int len, i; |
| #endif |
| /* reset, irq gpio info */ |
| if (np == NULL) { |
| pr_err("%s np NULL\n", __func__); |
| } else { |
| fuelgauge->pdata->fg_irq = of_get_named_gpio(np, "fuelgauge,fuel_int", 0); |
| if (fuelgauge->pdata->fg_irq < 0) |
| pr_err("%s error reading fg_irq = %d\n", |
| __func__, fuelgauge->pdata->fg_irq); |
| |
| ret = of_property_read_u32(np, "fuelgauge,fuel_alert_vol", |
| &fuelgauge->pdata->fuel_alert_vol); |
| if (ret < 0) { |
| fuelgauge->pdata->fuel_alert_vol = 3300; |
| pr_err("%s Default value of fuel_alert_vol : %d\n", |
| __func__, fuelgauge->pdata->fuel_alert_vol); |
| } |
| |
| ret = of_property_read_u32(np, "fuelgauge,fuel_alert_soc", |
| &fuelgauge->pdata->fuel_alert_soc); |
| if (ret < 0) |
| pr_err("%s error reading pdata->fuel_alert_soc %d\n", |
| __func__, ret); |
| |
| ret = of_property_read_u32(np, "fuelgauge,capacity_max", |
| &fuelgauge->pdata->capacity_max); |
| if (ret < 0) |
| pr_err("%s error reading capacity_max %d\n", __func__, ret); |
| |
| ret = of_property_read_u32(np, "fuelgauge,capacity_max_margin", |
| &fuelgauge->pdata->capacity_max_margin); |
| if (ret < 0) |
| pr_err("%s error reading capacity_max_margin %d\n", __func__, ret); |
| |
| ret = of_property_read_u32(np, "fuelgauge,capacity_min", |
| &fuelgauge->pdata->capacity_min); |
| if (ret < 0) |
| pr_err("%s error reading capacity_min %d\n", __func__, ret); |
| |
| ret = of_property_read_u32(np, "fuelgauge,capacity_calculation_type", |
| &fuelgauge->pdata->capacity_calculation_type); |
| if (ret < 0) |
| pr_err("%s error reading capacity_calculation_type %d\n", |
| __func__, ret); |
| ret = of_property_read_u32(np, "fuelgauge,capacity_full", |
| &fuelgauge->pdata->capacity_full); |
| if (ret < 0) |
| pr_err("%s error reading pdata->capacity_full %d\n", |
| __func__, ret); |
| |
| ret = of_property_read_u32(np, "fuelgauge,low_temp_limit", |
| &fuelgauge->low_temp_limit); |
| if (ret < 0) { |
| pr_err("%s There is no low temperature limit. Use default(100)\n", |
| __func__); |
| fuelgauge->low_temp_limit = 100; |
| } |
| |
| /* get topoff info */ |
| np = of_find_node_by_name(NULL, "cable-info"); |
| if (!np) { |
| pr_err("%s np NULL\n", __func__); |
| } else { |
| ret = of_property_read_u32(np, "full_check_current_1st", |
| &fuelgauge->topoff_current); |
| if (ret < 0) { |
| pr_err("%s fail to get topoff current %d\n", __func__, ret); |
| fuelgauge->topoff_current = 500; |
| } |
| } |
| |
| np = of_find_node_by_name(NULL, "battery"); |
| if (!np) { |
| pr_err("%s np NULL\n", __func__); |
| } else { |
| ret = of_property_read_string(np, |
| "battery,fuelgauge_name", |
| (char const **)&fuelgauge->pdata->fuelgauge_name); |
| } |
| |
| /* get battery node */ |
| np = of_find_node_by_name(NULL, "battery_params"); |
| if (!np) { |
| pr_err("%s battery_params node NULL\n", __func__); |
| } else { |
| #if !defined(CONFIG_BATTERY_AGE_FORECAST) |
| /* get battery_table */ |
| ret = of_property_read_u32_array(np, "battery,battery_table3", fuelgauge->info.battery_table3, 88); |
| if (ret < 0) |
| pr_err("%s error reading battery,battery_table3\n", __func__); |
| |
| ret = of_property_read_u32_array(np, "battery,battery_table4", fuelgauge->info.battery_table4, 22); |
| if (ret < 0) |
| pr_err("%s error reading battery,battery_table4\n", __func__); |
| |
| ret = of_property_read_u32_array(np, "battery,batcap", fuelgauge->info.batcap, 4); |
| if (ret < 0) |
| pr_err("%s error reading battery,batcap\n", __func__); |
| |
| ret = of_property_read_u32_array(np, "battery,accum", fuelgauge->info.accum, 2); |
| if (ret < 0) { |
| fuelgauge->info.accum[0]=0x00; // REG 0x44 |
| fuelgauge->info.accum[1]=0x08; // REG 0x45 |
| pr_err("%s There is no accumulative rate value in DT. set to the default value(0x800)\n", __func__); |
| } |
| |
| ret = of_property_read_u32_array(np, "battery,soc_arr_val", fuelgauge->info.soc_arr_val, 22); |
| if (ret < 0) |
| pr_err("%s error reading battery,soc_arr_val\n", __func__); |
| |
| ret = of_property_read_u32_array(np, "battery,ocv_arr_val", fuelgauge->info.ocv_arr_val, 22); |
| if (ret < 0) |
| pr_err("%s error reading battery,ocv_arr_val\n", __func__); |
| |
| #else |
| of_get_property(np, "battery,battery_data", &len); |
| fuelgauge->fg_num_age_step = len / sizeof(fg_age_data_info_t); |
| fuelgauge->age_data_info = kzalloc(len, GFP_KERNEL); |
| ret = of_property_read_u32_array(np, "battery,battery_data", |
| (int *)fuelgauge->age_data_info, len/sizeof(int)); |
| |
| pr_err("%s: [Long life] fuelgauge->fg_num_age_step %d \n", |
| __func__,fuelgauge->fg_num_age_step); |
| |
| if ((sizeof(fg_age_data_info_t) * fuelgauge->fg_num_age_step) != len) { |
| pr_err("%s: The Long life variables and the data in device tree does not match\n", __func__); |
| BUG(); |
| } |
| |
| for(i=0 ; i < fuelgauge->fg_num_age_step ; i++){ |
| pr_err("%s: [Long life] age_step = %d, table3[0] %d, table4[0] %d, batcap[0] %02x, accum[0] %02x, soc_arr[0] %d, ocv_arr[0] %d, volt_tun : %02x\n", |
| __func__, i, |
| fuelgauge->age_data_info[i].battery_table3[0], |
| fuelgauge->age_data_info[i].battery_table4[0], |
| fuelgauge->age_data_info[i].batcap[0], |
| fuelgauge->age_data_info[i].accum[0], |
| fuelgauge->age_data_info[i].soc_arr_val[0], |
| fuelgauge->age_data_info[i].ocv_arr_val[0], |
| fuelgauge->age_data_info[i].volt_mode_tunning); |
| } |
| #endif |
| } |
| } |
| |
| return 0; |
| } |
| |
| static struct of_device_id s2mu205_fuelgauge_match_table[] = { |
| { .compatible = "samsung,s2mu205-fuelgauge",}, |
| {}, |
| }; |
| #else |
| static int s2mu205_fuelgauge_parse_dt(struct s2mu205_fuelgauge_data *fuelgauge) |
| { |
| return -ENOSYS; |
| } |
| |
| #define s2mu205_fuelgauge_match_table NULL |
| #endif /* CONFIG_OF */ |
| |
| static const struct power_supply_desc s2mu205_fuelgauge_power_supply_desc = { |
| .name = "s2mu205-fuelgauge", |
| .type = POWER_SUPPLY_TYPE_UNKNOWN, |
| .properties = s2mu205_fuelgauge_props, |
| .num_properties = ARRAY_SIZE(s2mu205_fuelgauge_props), |
| .get_property = s2mu205_fg_get_property, |
| .set_property = s2mu205_fg_set_property, |
| }; |
| |
| static int s2mu205_fuelgauge_probe(struct i2c_client *client, |
| const struct i2c_device_id *id) |
| { |
| struct i2c_adapter *adapter = to_i2c_adapter(client->dev.parent); |
| struct s2mu205_fuelgauge_data *fuelgauge; |
| union power_supply_propval raw_soc_val; |
| struct power_supply_config fuelgauge_cfg = {}; |
| int ret = 0; |
| u8 temp = 0; |
| |
| pr_info("%s: S2MU205 Fuelgauge Driver Loading\n", __func__); |
| |
| if (!i2c_check_functionality(adapter, I2C_FUNC_SMBUS_BYTE)) |
| return -EIO; |
| |
| fuelgauge = kzalloc(sizeof(*fuelgauge), GFP_KERNEL); |
| if (!fuelgauge) |
| return -ENOMEM; |
| |
| mutex_init(&fuelgauge->fg_lock); |
| |
| fuelgauge->i2c = client; |
| |
| if (client->dev.of_node) { |
| fuelgauge->pdata = devm_kzalloc(&client->dev, sizeof(*(fuelgauge->pdata)), |
| GFP_KERNEL); |
| if (!fuelgauge->pdata) { |
| dev_err(&client->dev, "Failed to allocate memory\n"); |
| ret = -ENOMEM; |
| goto err_parse_dt_nomem; |
| } |
| ret = s2mu205_fuelgauge_parse_dt(fuelgauge); |
| if (ret < 0) |
| goto err_parse_dt; |
| } else { |
| fuelgauge->pdata = client->dev.platform_data; |
| } |
| |
| i2c_set_clientdata(client, fuelgauge); |
| |
| if (fuelgauge->pdata->fuelgauge_name == NULL) |
| fuelgauge->pdata->fuelgauge_name = "s2mu205-fuelgauge"; |
| |
| fuelgauge_cfg.drv_data = fuelgauge; |
| |
| /* FG Revision Value Setting */ |
| fuelgauge->revision = 0; |
| s2mu205_read_reg_byte(fuelgauge->i2c, 0x48, &temp); |
| fuelgauge->revision = (temp & 0xF0) >> 4; |
| |
| pr_info("%s: S2MU205 Fuelgauge revision: 0x%x, reg 0x48 = 0x%x\n", |
| __func__, fuelgauge->revision, temp); |
| |
| fuelgauge->info.soc = 0; |
| |
| /* default CURRENT_MODE setting */ |
| fuelgauge->mode = CURRENT_MODE; |
| s2mu205_write_and_verify_reg_byte(fuelgauge->i2c, 0x4A, 0x10); |
| s2mu205_update_reg_byte(fuelgauge->i2c, 0x4B, 0x00, 0x70); |
| |
| /* capacity Max */ |
| fuelgauge->capacity_max = fuelgauge->pdata->capacity_max; |
| |
| raw_soc_val.intval = s2mu205_get_rawsoc(fuelgauge); |
| raw_soc_val.intval = raw_soc_val.intval / 10; |
| |
| if (raw_soc_val.intval > fuelgauge->capacity_max) |
| s2mu205_fg_calculate_dynamic_scale(fuelgauge, 100); |
| |
| #if (TEMP_COMPEN) |
| fuelgauge->init_start = 1; |
| fuelgauge->flag_mapping = false; |
| #endif |
| #if (BATCAP_LEARN) |
| fuelgauge->learn_start = false; |
| fuelgauge->cond1_ok = false; |
| fuelgauge->c1_count = 0; |
| fuelgauge->c2_count = 0; |
| #endif |
| |
| s2mu205_init_regs(fuelgauge); |
| |
| fuelgauge->psy_fg = power_supply_register( |
| &client->dev, &s2mu205_fuelgauge_power_supply_desc, &fuelgauge_cfg); |
| if (!fuelgauge->psy_fg) { |
| pr_err("%s: Failed to Register psy_fg\n", __func__); |
| ret = PTR_ERR(fuelgauge->psy_fg); |
| goto err_data_free; |
| } |
| |
| fuelgauge->is_fuel_alerted = false; |
| if (fuelgauge->pdata->fuel_alert_soc >= 0) { |
| s2mu205_fuelalert_init(fuelgauge); |
| wake_lock_init(&fuelgauge->fuel_alert_wake_lock, |
| WAKE_LOCK_SUSPEND, "fuel_alerted"); |
| |
| if (fuelgauge->pdata->fg_irq > 0) { |
| INIT_DELAYED_WORK(&fuelgauge->isr_work, s2mu205_fg_isr_work); |
| |
| fuelgauge->fg_irq = gpio_to_irq(fuelgauge->pdata->fg_irq); |
| dev_info(&client->dev, "%s : fg_irq = %d\n", __func__, fuelgauge->fg_irq); |
| if (fuelgauge->fg_irq > 0) { |
| ret = request_threaded_irq(fuelgauge->fg_irq, |
| NULL, s2mu205_fg_irq_thread, |
| IRQF_TRIGGER_FALLING | IRQF_TRIGGER_RISING | IRQF_ONESHOT, |
| "fuelgauge-irq", fuelgauge); |
| if (ret) { |
| dev_err(&client->dev, "%s: Failed to Request IRQ\n", __func__); |
| goto err_supply_unreg; |
| } |
| |
| ret = enable_irq_wake(fuelgauge->fg_irq); |
| if (ret < 0) |
| dev_err(&client->dev, "%s: Failed to Enable Wakeup Source(%d)\n", |
| __func__, ret); |
| } else { |
| dev_err(&client->dev, "%s: Failed gpio_to_irq(%d)\n", __func__, fuelgauge->fg_irq); |
| goto err_supply_unreg; |
| } |
| } |
| } |
| |
| fuelgauge->cable_type = SEC_BATTERY_CABLE_NONE; |
| fuelgauge->sleep_initial_update_of_soc = false; |
| fuelgauge->initial_update_of_soc = true; |
| #if (TEMP_COMPEN) || (BATCAP_LEARN) |
| fuelgauge->bat_charging = false; |
| #endif |
| fuelgauge->probe_done = true; |
| |
| pr_info("%s: S2MU205 Fuelgauge Driver Loaded\n", __func__); |
| return 0; |
| |
| err_supply_unreg: |
| power_supply_unregister(fuelgauge->psy_fg); |
| err_data_free: |
| if (client->dev.of_node) |
| kfree(fuelgauge->pdata); |
| |
| err_parse_dt: |
| err_parse_dt_nomem: |
| mutex_destroy(&fuelgauge->fg_lock); |
| kfree(fuelgauge); |
| |
| return ret; |
| } |
| |
| static const struct i2c_device_id s2mu205_fuelgauge_id[] = { |
| {"s2mu205-fuelgauge", 0}, |
| {} |
| }; |
| |
| static void s2mu205_fuelgauge_shutdown(struct i2c_client *client) |
| { |
| |
| } |
| |
| static int s2mu205_fuelgauge_remove(struct i2c_client *client) |
| { |
| struct s2mu205_fuelgauge_data *fuelgauge = i2c_get_clientdata(client); |
| |
| if (fuelgauge->pdata->fuel_alert_soc >= 0) |
| wake_lock_destroy(&fuelgauge->fuel_alert_wake_lock); |
| |
| return 0; |
| } |
| |
| #if defined CONFIG_PM |
| static int s2mu205_fuelgauge_suspend(struct device *dev) |
| { |
| return 0; |
| } |
| |
| static int s2mu205_fuelgauge_resume(struct device *dev) |
| { |
| struct s2mu205_fuelgauge_data *fuelgauge = dev_get_drvdata(dev); |
| |
| fuelgauge->sleep_initial_update_of_soc = true; |
| |
| return 0; |
| } |
| #else |
| #define s2mu205_fuelgauge_suspend NULL |
| #define s2mu205_fuelgauge_resume NULL |
| #endif |
| |
| static SIMPLE_DEV_PM_OPS(s2mu205_fuelgauge_pm_ops, s2mu205_fuelgauge_suspend, |
| s2mu205_fuelgauge_resume); |
| |
| static struct i2c_driver s2mu205_fuelgauge_driver = { |
| .driver = { |
| .name = "s2mu205-fuelgauge", |
| .owner = THIS_MODULE, |
| .pm = &s2mu205_fuelgauge_pm_ops, |
| .of_match_table = s2mu205_fuelgauge_match_table, |
| }, |
| .probe = s2mu205_fuelgauge_probe, |
| .remove = s2mu205_fuelgauge_remove, |
| .shutdown = s2mu205_fuelgauge_shutdown, |
| .id_table = s2mu205_fuelgauge_id, |
| }; |
| |
| static int __init s2mu205_fuelgauge_init(void) |
| { |
| pr_info("%s: S2MU205 Fuelgauge Init\n", __func__); |
| return i2c_add_driver(&s2mu205_fuelgauge_driver); |
| } |
| |
| static void __exit s2mu205_fuelgauge_exit(void) |
| { |
| i2c_del_driver(&s2mu205_fuelgauge_driver); |
| } |
| module_init(s2mu205_fuelgauge_init); |
| module_exit(s2mu205_fuelgauge_exit); |
| |
| MODULE_DESCRIPTION("Samsung S2MU205 Fuel Gauge Driver"); |
| MODULE_AUTHOR("Samsung Electronics"); |
| MODULE_LICENSE("GPL"); |