| TI SOC ECAP based APWM controller |
| |
| Required properties: |
| - compatible: Must be "ti,<soc>-ecap". |
| for am33xx - compatible = "ti,am33xx-ecap"; |
| for da850 - compatible = "ti,da850-ecap", "ti,am33xx-ecap"; |
| - #pwm-cells: Should be 3. Number of cells being used to specify PWM property. |
| First cell specifies the per-chip index of the PWM to use, the second |
| cell is the period in nanoseconds and bit 0 in the third cell is used to |
| encode the polarity of PWM output. Set bit 0 of the third in PWM specifier |
| to 1 for inverse polarity & set to 0 for normal polarity. |
| - reg: physical base address and size of the registers map. |
| |
| Optional properties: |
| - ti,hwmods: Name of the hwmod associated to the ECAP: |
| "ecap<x>", <x> being the 0-based instance number from the HW spec |
| |
| Example: |
| |
| ecap0: ecap@0 { /* ECAP on am33xx */ |
| compatible = "ti,am33xx-ecap"; |
| #pwm-cells = <3>; |
| reg = <0x48300100 0x80>; |
| ti,hwmods = "ecap0"; |
| }; |
| |
| ecap0: ecap@0 { /* ECAP on da850 */ |
| compatible = "ti,da850-ecap", "ti,am33xx-ecap"; |
| #pwm-cells = <3>; |
| reg = <0x306000 0x80>; |
| }; |