| * AT91's Analog to Digital Converter (ADC) |
| |
| Required properties: |
| - compatible: Should be "atmel,at91sam9260-adc" |
| - reg: Should contain ADC registers location and length |
| - interrupts: Should contain the IRQ line for the ADC |
| - atmel,adc-channel-base: Offset of the first channel data register |
| - atmel,adc-channels-used: Bitmask of the channels muxed and enable for this |
| device |
| - atmel,adc-drdy-mask: Mask of the DRDY interruption in the ADC |
| - atmel,adc-num-channels: Number of channels available in the ADC |
| - atmel,adc-startup-time: Startup Time of the ADC in microseconds as |
| defined in the datasheet |
| - atmel,adc-status-register: Offset of the Interrupt Status Register |
| - atmel,adc-trigger-register: Offset of the Trigger Register |
| - atmel,adc-vref: Reference voltage in millivolts for the conversions |
| |
| Optional properties: |
| - atmel,adc-use-external: Boolean to enable of external triggers |
| |
| Optional trigger Nodes: |
| - Required properties: |
| * trigger-name: Name of the trigger exposed to the user |
| * trigger-value: Value to put in the Trigger register |
| to activate this trigger |
| - Optional properties: |
| * trigger-external: Is the trigger an external trigger? |
| |
| Examples: |
| adc0: adc@fffb0000 { |
| compatible = "atmel,at91sam9260-adc"; |
| reg = <0xfffb0000 0x100>; |
| interrupts = <20 4>; |
| atmel,adc-channel-base = <0x30>; |
| atmel,adc-channels-used = <0xff>; |
| atmel,adc-drdy-mask = <0x10000>; |
| atmel,adc-num-channels = <8>; |
| atmel,adc-startup-time = <40>; |
| atmel,adc-status-register = <0x1c>; |
| atmel,adc-trigger-register = <0x08>; |
| atmel,adc-use-external; |
| atmel,adc-vref = <3300>; |
| |
| trigger@0 { |
| trigger-name = "external-rising"; |
| trigger-value = <0x1>; |
| trigger-external; |
| }; |
| trigger@1 { |
| trigger-name = "external-falling"; |
| trigger-value = <0x2>; |
| trigger-external; |
| }; |
| |
| trigger@2 { |
| trigger-name = "external-any"; |
| trigger-value = <0x3>; |
| trigger-external; |
| }; |
| |
| trigger@3 { |
| trigger-name = "continuous"; |
| trigger-value = <0x6>; |
| }; |
| }; |