Staging: hv: vmbus: Increase the timeout for some critical calls

Increase the timeout for some critical calls. In testing we discovered that the
current timeout of 1 second was insufficient under some conditions.

Signed-off-by: K. Y. Srinivasan <kys@microsoft.com>
Signed-off-by: Haiyang Zhang <haiyangz@microsoft.com>
Signed-off-by: Abhishek Kane <v-abkane@microsoft.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
diff --git a/drivers/staging/hv/channel.c b/drivers/staging/hv/channel.c
index 5a2a947..69b5641 100644
--- a/drivers/staging/hv/channel.c
+++ b/drivers/staging/hv/channel.c
@@ -480,7 +480,7 @@
 
 		}
 	}
-	t = wait_for_completion_timeout(&msginfo->waitevent, HZ);
+	t = wait_for_completion_timeout(&msginfo->waitevent, 5*HZ);
 	BUG_ON(t == 0);
 
 
@@ -530,7 +530,7 @@
 			       sizeof(struct vmbus_channel_gpadl_teardown));
 
 	BUG_ON(ret != 0);
-	t = wait_for_completion_timeout(&info->waitevent, HZ);
+	t = wait_for_completion_timeout(&info->waitevent, 5*HZ);
 	BUG_ON(t == 0);
 
 	/* Received a torndown response */