Input: synaptics - fix reporting of min coordinates

We were testing wrong bit in the extended capability query.

Reported-by: Daniel Kurtz <djkurtz@chromium.org>
Signed-off-by: Dmitry Torokhov <dtor@mail.ru>
diff --git a/drivers/input/mouse/synaptics.h b/drivers/input/mouse/synaptics.h
index a4394e1..ca040aa 100644
--- a/drivers/input/mouse/synaptics.h
+++ b/drivers/input/mouse/synaptics.h
@@ -79,7 +79,7 @@
 #define SYN_CAP_CLICKPAD(ex0c)		((ex0c) & 0x100000) /* 1-button ClickPad */
 #define SYN_CAP_CLICKPAD2BTN(ex0c)	((ex0c) & 0x000100) /* 2-button ClickPad */
 #define SYN_CAP_MAX_DIMENSIONS(ex0c)	((ex0c) & 0x020000)
-#define SYN_CAP_MIN_DIMENSIONS(ex0c)	((ex0c) & 0x000200)
+#define SYN_CAP_MIN_DIMENSIONS(ex0c)	((ex0c) & 0x002000)
 #define SYN_CAP_ADV_GESTURE(ex0c)	((ex0c) & 0x080000)
 #define SYN_CAP_REDUCED_FILTERING(ex0c)	((ex0c) & 0x000400)