sched: adjust when cpu_active and cpuset configurations are updated during cpu on/offlining
Currently, when a cpu goes down, cpu_active is cleared before
CPU_DOWN_PREPARE starts and cpuset configuration is updated from a
default priority cpu notifier. When a cpu is coming up, it's set
before CPU_ONLINE but cpuset configuration again is updated from the
same cpu notifier.
For cpu notifiers, this presents an inconsistent state. Threads which
a CPU_DOWN_PREPARE notifier expects to be bound to the CPU can be
migrated to other cpus because the cpu is no more inactive.
Fix it by updating cpu_active in the highest priority cpu notifier and
cpuset configuration in the second highest when a cpu is coming up.
Down path is updated similarly. This guarantees that all other cpu
notifiers see consistent cpu_active and cpuset configuration.
cpuset_track_online_cpus() notifier is converted to
cpuset_update_active_cpus() which just updates the configuration and
now called from cpuset_cpu_[in]active() notifiers registered from
sched_init_smp(). If cpuset is disabled, cpuset_update_active_cpus()
degenerates into partition_sched_domains() making separate notifier
for !CONFIG_CPUSETS unnecessary.
This problem is triggered by cmwq. During CPU_DOWN_PREPARE, hotplug
callback creates a kthread and kthread_bind()s it to the target cpu,
and the thread is expected to run on that cpu.
* Ingo's test discovered __cpuinit/exit markups were incorrect.
Fixed.
Signed-off-by: Tejun Heo <tj@kernel.org>
Acked-by: Peter Zijlstra <a.p.zijlstra@chello.nl>
Cc: Rusty Russell <rusty@rustcorp.com.au>
Cc: Ingo Molnar <mingo@elte.hu>
Cc: Paul Menage <menage@google.com>
diff --git a/kernel/cpuset.c b/kernel/cpuset.c
index 02b9611..05727dc 100644
--- a/kernel/cpuset.c
+++ b/kernel/cpuset.c
@@ -2113,31 +2113,17 @@
* but making no active use of cpusets.
*
* This routine ensures that top_cpuset.cpus_allowed tracks
- * cpu_online_map on each CPU hotplug (cpuhp) event.
+ * cpu_active_mask on each CPU hotplug (cpuhp) event.
*
* Called within get_online_cpus(). Needs to call cgroup_lock()
* before calling generate_sched_domains().
*/
-static int cpuset_track_online_cpus(struct notifier_block *unused_nb,
- unsigned long phase, void *unused_cpu)
+void __cpuexit cpuset_update_active_cpus(void)
{
struct sched_domain_attr *attr;
cpumask_var_t *doms;
int ndoms;
- switch (phase) {
- case CPU_ONLINE:
- case CPU_ONLINE_FROZEN:
- case CPU_DOWN_PREPARE:
- case CPU_DOWN_PREPARE_FROZEN:
- case CPU_DOWN_FAILED:
- case CPU_DOWN_FAILED_FROZEN:
- break;
-
- default:
- return NOTIFY_DONE;
- }
-
cgroup_lock();
mutex_lock(&callback_mutex);
cpumask_copy(top_cpuset.cpus_allowed, cpu_active_mask);
@@ -2148,8 +2134,6 @@
/* Have scheduler rebuild the domains */
partition_sched_domains(ndoms, doms, attr);
-
- return NOTIFY_OK;
}
#ifdef CONFIG_MEMORY_HOTPLUG
@@ -2203,7 +2187,6 @@
cpumask_copy(top_cpuset.cpus_allowed, cpu_active_mask);
top_cpuset.mems_allowed = node_states[N_HIGH_MEMORY];
- hotcpu_notifier(cpuset_track_online_cpus, 0);
hotplug_memory_notifier(cpuset_track_online_nodes, 10);
cpuset_wq = create_singlethread_workqueue("cpuset");