omap_uwire: SPI_CPHA mode bugfix

The omap_uwire controller driver handles SPI_CPHA incorrectly;
It should mean:

  CPHA=0 ... sample at leading edge of clock
  CPHA=1 ... sample at trailing edge of clock

This bug has been masked by inverse bugs in layered drivers;
and was uncovered by running some of them on non-OMAP hardware.

Signed-off-by: David Brownell <dbrownell@users.sourceforge.net>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
diff --git a/drivers/spi/omap_uwire.c b/drivers/spi/omap_uwire.c
index 96f62b2..95183e1 100644
--- a/drivers/spi/omap_uwire.c
+++ b/drivers/spi/omap_uwire.c
@@ -358,11 +358,11 @@
 	switch (spi->mode & (SPI_CPOL | SPI_CPHA)) {
 	case SPI_MODE_0:
 	case SPI_MODE_3:
-		flags |= UWIRE_WRITE_RISING_EDGE | UWIRE_READ_FALLING_EDGE;
+		flags |= UWIRE_WRITE_FALLING_EDGE | UWIRE_READ_RISING_EDGE;
 		break;
 	case SPI_MODE_1:
 	case SPI_MODE_2:
-		flags |= UWIRE_WRITE_FALLING_EDGE | UWIRE_READ_RISING_EDGE;
+		flags |= UWIRE_WRITE_RISING_EDGE | UWIRE_READ_FALLING_EDGE;
 		break;
 	}