| * linux/drivers/thermal/cpu_cooling.c |
| * |
| * Copyright (C) 2012 Samsung Electronics Co., Ltd(http://www.samsung.com) |
| * Copyright (C) 2012 Amit Daniel <amit.kachhap@linaro.org> |
| * |
| * Copyright (C) 2014 Viresh Kumar <viresh.kumar@linaro.org> |
| * |
| * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
| * This program is free software; you can redistribute it and/or modify |
| * it under the terms of the GNU General Public License as published by |
| * the Free Software Foundation; version 2 of the License. |
| * |
| * This program is distributed in the hope that it will be useful, but |
| * WITHOUT ANY WARRANTY; without even the implied warranty of |
| * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU |
| * General Public License for more details. |
| * |
| * You should have received a copy of the GNU General Public License along |
| * with this program; if not, write to the Free Software Foundation, Inc., |
| * 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA. |
| * |
| * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
| */ |
| #include <linux/module.h> |
| #include <linux/thermal.h> |
| #include <linux/cpufreq.h> |
| #include <linux/err.h> |
| #include <linux/idr.h> |
| #include <linux/pm_opp.h> |
| #include <linux/slab.h> |
| #include <linux/cpu.h> |
| #include <linux/cpu_cooling.h> |
| #include <linux/debug-snapshot.h> |
| |
| #include <trace/events/thermal.h> |
| |
| #include <soc/samsung/tmu.h> |
| #include <soc/samsung/cal-if.h> |
| #include <soc/samsung/ect_parser.h> |
| |
| #include <dt-bindings/clock/exynos9820.h> |
| /* |
| * Cooling state <-> CPUFreq frequency |
| * |
| * Cooling states are translated to frequencies throughout this driver and this |
| * is the relation between them. |
| * |
| * Highest cooling state corresponds to lowest possible frequency. |
| * |
| * i.e. |
| * level 0 --> 1st Max Freq |
| * level 1 --> 2nd Max Freq |
| * ... |
| */ |
| |
| /** |
| * struct freq_table - frequency table along with power entries |
| * @frequency: frequency in KHz |
| * @power: power in mW |
| * |
| * This structure is built when the cooling device registers and helps |
| * in translating frequency to power and vice versa. |
| */ |
| struct freq_table { |
| u32 frequency; |
| u32 power; |
| }; |
| |
| static BLOCKING_NOTIFIER_HEAD(cpu_notifier); |
| |
| static enum tmu_noti_state_t cpu_tstate = TMU_NORMAL; |
| |
| /** |
| * struct time_in_idle - Idle time stats |
| * @time: previous reading of the absolute time that this cpu was idle |
| * @timestamp: wall time of the last invocation of get_cpu_idle_time_us() |
| */ |
| struct time_in_idle { |
| u64 time; |
| u64 timestamp; |
| }; |
| |
| static DEFINE_IDA(cpufreq_ida); |
| static DEFINE_MUTEX(cooling_list_lock); |
| static LIST_HEAD(cpufreq_cdev_list); |
| |
| /* Below code defines functions to be used for cpufreq as cooling device */ |
| |
| /** |
| * get_level: Find the level for a particular frequency |
| * @cpufreq_cdev: cpufreq_cdev for which the property is required |
| * @freq: Frequency |
| * |
| * Return: level corresponding to the frequency. |
| */ |
| static unsigned long get_level(struct cpufreq_cooling_device *cpufreq_cdev, |
| unsigned int freq) |
| { |
| struct freq_table *freq_table = cpufreq_cdev->freq_table; |
| unsigned long level; |
| |
| for (level = 1; level <= cpufreq_cdev->max_level; level++) |
| if (freq > freq_table[level].frequency) |
| break; |
| |
| return level - 1; |
| } |
| |
| /** |
| * cpufreq_cooling_get_level - for a given cpu, return the cooling level. |
| * @cpu: cpu for which the level is required |
| * @freq: the frequency of interest |
| * |
| * This function will match the cooling level corresponding to the |
| * requested @freq and return it. |
| * |
| * Return: The matched cooling level on success or THERMAL_CSTATE_INVALID |
| * otherwise. |
| */ |
| unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq) |
| { |
| struct cpufreq_cooling_device *cpufreq_cdev; |
| |
| mutex_lock(&cooling_list_lock); |
| list_for_each_entry(cpufreq_cdev, &cpufreq_cdev_list, node) { |
| if (cpumask_test_cpu(cpu, cpufreq_cdev->policy->related_cpus)) { |
| unsigned long level = get_level(cpufreq_cdev, freq); |
| |
| mutex_unlock(&cooling_list_lock); |
| return level; |
| } |
| } |
| mutex_unlock(&cooling_list_lock); |
| |
| pr_err("%s: cpu:%d not part of any cooling device\n", __func__, cpu); |
| return THERMAL_CSTATE_INVALID; |
| } |
| EXPORT_SYMBOL_GPL(cpufreq_cooling_get_level); |
| |
| /** |
| * cpufreq_thermal_notifier - notifier callback for cpufreq policy change. |
| * @nb: struct notifier_block * with callback info. |
| * @event: value showing cpufreq event for which this function invoked. |
| * @data: callback-specific data |
| * |
| * Callback to hijack the notification on cpufreq policy transition. |
| * Every time there is a change in policy, we will intercept and |
| * update the cpufreq policy with thermal constraints. |
| * |
| * Return: 0 (success) |
| */ |
| static int cpufreq_thermal_notifier(struct notifier_block *nb, |
| unsigned long event, void *data) |
| { |
| struct cpufreq_policy *policy = data; |
| unsigned long clipped_freq; |
| struct cpufreq_cooling_device *cpufreq_cdev; |
| |
| if (event != CPUFREQ_ADJUST) |
| return NOTIFY_DONE; |
| |
| mutex_lock(&cooling_list_lock); |
| list_for_each_entry(cpufreq_cdev, &cpufreq_cdev_list, node) { |
| /* |
| * A new copy of the policy is sent to the notifier and can't |
| * compare that directly. |
| */ |
| if (policy->cpu != cpufreq_cdev->policy->cpu) |
| continue; |
| |
| /* |
| * policy->max is the maximum allowed frequency defined by user |
| * and clipped_freq is the maximum that thermal constraints |
| * allow. |
| * |
| * If clipped_freq is lower than policy->max, then we need to |
| * readjust policy->max. |
| * |
| * But, if clipped_freq is greater than policy->max, we don't |
| * need to do anything. |
| */ |
| clipped_freq = cpufreq_cdev->clipped_freq; |
| |
| if (policy->max > clipped_freq) { |
| cpufreq_verify_within_limits(policy, 0, clipped_freq); |
| dbg_snapshot_thermal(NULL, 0, cpufreq_cdev->cdev->type, clipped_freq); |
| } |
| break; |
| } |
| mutex_unlock(&cooling_list_lock); |
| |
| return NOTIFY_OK; |
| } |
| |
| /** |
| * update_freq_table() - Update the freq table with power numbers |
| * @cpufreq_cdev: the cpufreq cooling device in which to update the table |
| * @capacitance: dynamic power coefficient for these cpus |
| * |
| * Update the freq table with power numbers. This table will be used in |
| * cpu_power_to_freq() and cpu_freq_to_power() to convert between power and |
| * frequency efficiently. Power is stored in mW, frequency in KHz. The |
| * resulting table is in descending order. |
| * |
| * Return: 0 on success, -EINVAL if there are no OPPs for any CPUs, |
| * or -ENOMEM if we run out of memory. |
| */ |
| static int update_freq_table(struct cpufreq_cooling_device *cpufreq_cdev, |
| u32 capacitance) |
| { |
| struct freq_table *freq_table = cpufreq_cdev->freq_table; |
| struct dev_pm_opp *opp; |
| struct device *dev = NULL; |
| int num_opps = 0, cpu = cpufreq_cdev->policy->cpu, i; |
| |
| dev = get_cpu_device(cpu); |
| if (unlikely(!dev)) { |
| dev_warn(&cpufreq_cdev->cdev->device, |
| "No cpu device for cpu %d\n", cpu); |
| return -ENODEV; |
| } |
| |
| num_opps = dev_pm_opp_get_opp_count(dev); |
| if (num_opps < 0) |
| return num_opps; |
| |
| /* |
| * The cpufreq table is also built from the OPP table and so the count |
| * should match. |
| */ |
| if (num_opps != cpufreq_cdev->max_level + 1) { |
| dev_warn(dev, "Number of OPPs not matching with max_levels\n"); |
| return -EINVAL; |
| } |
| |
| for (i = 0; i <= cpufreq_cdev->max_level; i++) { |
| unsigned long freq = freq_table[i].frequency * 1000; |
| u32 freq_mhz = freq_table[i].frequency / 1000; |
| u64 power; |
| u32 voltage_mv; |
| |
| /* |
| * Find ceil frequency as 'freq' may be slightly lower than OPP |
| * freq due to truncation while converting to kHz. |
| */ |
| opp = dev_pm_opp_find_freq_ceil(dev, &freq); |
| if (IS_ERR(opp)) { |
| dev_err(dev, "failed to get opp for %lu frequency\n", |
| freq); |
| return -EINVAL; |
| } |
| |
| voltage_mv = dev_pm_opp_get_voltage(opp) / 1000; |
| dev_pm_opp_put(opp); |
| |
| /* |
| * Do the multiplication with MHz and millivolt so as |
| * to not overflow. |
| */ |
| power = (u64)capacitance * freq_mhz * voltage_mv * voltage_mv; |
| do_div(power, 1000000000); |
| |
| /* power is stored in mW */ |
| freq_table[i].power = power; |
| } |
| |
| return 0; |
| } |
| |
| static int build_static_power_table(struct device_node *np, struct cpufreq_cooling_device *cpufreq_cdev) |
| { |
| int i, j; |
| int ratio, asv_group, cal_id, ret = 0; |
| |
| void *gen_block; |
| struct ect_gen_param_table *volt_temp_param = NULL, *asv_param = NULL; |
| int ratio_table[16] = { 0, 18, 22, 27, 33, 40, 49, 60, 73, 89, 108, 131, 159, 194, 232, 250}; |
| |
| ret = of_property_read_u32(np, "cal-id", &cal_id); |
| if (ret) { |
| pr_err("%s: Failed to get cal-id\n", __func__); |
| return -EINVAL; |
| } |
| |
| ratio = cal_asv_get_ids_info(cal_id); |
| asv_group = cal_asv_get_grp(cal_id); |
| |
| if (asv_group < 0 || asv_group > 15) |
| asv_group = 0; |
| |
| if (!ratio) |
| ratio = ratio_table[asv_group]; |
| |
| gen_block = ect_get_block("GEN"); |
| if (gen_block == NULL) { |
| pr_err("%s: Failed to get gen block from ECT\n", __func__); |
| return -EINVAL; |
| } |
| |
| #if defined(CONFIG_SOC_EXYNOS9820) |
| if (cal_id == ACPM_DVFS_CPUCL1) { |
| volt_temp_param = ect_gen_param_get_table(gen_block, "DTM_MID_VOLT_TEMP"); |
| asv_param = ect_gen_param_get_table(gen_block, "DTM_MID_ASV"); |
| } else if (cal_id == ACPM_DVFS_CPUCL2) { |
| volt_temp_param = ect_gen_param_get_table(gen_block, "DTM_BIG_VOLT_TEMP"); |
| asv_param = ect_gen_param_get_table(gen_block, "DTM_BIG_ASV"); |
| } |
| #else |
| volt_temp_param = ect_gen_param_get_table(gen_block, "DTM_BIG_VOLT_TEMP"); |
| asv_param = ect_gen_param_get_table(gen_block, "DTM_BIG_ASV"); |
| #endif |
| |
| if (volt_temp_param && asv_param) { |
| cpufreq_cdev->var_volt_size = volt_temp_param->num_of_row - 1; |
| cpufreq_cdev->var_temp_size = volt_temp_param->num_of_col - 1; |
| |
| cpufreq_cdev->var_coeff = kzalloc(sizeof(int) * |
| volt_temp_param->num_of_row * |
| volt_temp_param->num_of_col, |
| GFP_KERNEL); |
| if (!cpufreq_cdev->var_coeff) |
| goto err_mem; |
| |
| cpufreq_cdev->asv_coeff = kzalloc(sizeof(int) * |
| asv_param->num_of_row * |
| asv_param->num_of_col, |
| GFP_KERNEL); |
| if (!cpufreq_cdev->asv_coeff) |
| goto free_var_coeff; |
| |
| cpufreq_cdev->var_table = kzalloc(sizeof(int) * |
| volt_temp_param->num_of_row * |
| volt_temp_param->num_of_col, |
| GFP_KERNEL); |
| if (!cpufreq_cdev->var_table) |
| goto free_asv_coeff; |
| |
| memcpy(cpufreq_cdev->var_coeff, volt_temp_param->parameter, |
| sizeof(int) * volt_temp_param->num_of_row * volt_temp_param->num_of_col); |
| memcpy(cpufreq_cdev->asv_coeff, asv_param->parameter, |
| sizeof(int) * asv_param->num_of_row * asv_param->num_of_col); |
| memcpy(cpufreq_cdev->var_table, volt_temp_param->parameter, |
| sizeof(int) * volt_temp_param->num_of_row * volt_temp_param->num_of_col); |
| } else { |
| pr_err("%s: Failed to get param table from ECT\n", __func__); |
| return -EINVAL; |
| } |
| |
| for (i = 1; i <= cpufreq_cdev->var_volt_size; i++) { |
| long asv_coeff = (long)cpufreq_cdev->asv_coeff[3 * i + 0] * asv_group * asv_group |
| + (long)cpufreq_cdev->asv_coeff[3 * i + 1] * asv_group |
| + (long)cpufreq_cdev->asv_coeff[3 * i + 2]; |
| asv_coeff = asv_coeff / 100; |
| |
| for (j = 1; j <= cpufreq_cdev->var_temp_size; j++) { |
| long var_coeff = (long)cpufreq_cdev->var_coeff[i * (cpufreq_cdev->var_temp_size + 1) + j]; |
| var_coeff = ratio * var_coeff * asv_coeff; |
| var_coeff = var_coeff / 100000; |
| cpufreq_cdev->var_table[i * (cpufreq_cdev->var_temp_size + 1) + j] = (int)var_coeff; |
| } |
| } |
| |
| return 0; |
| |
| free_asv_coeff: |
| kfree(cpufreq_cdev->asv_coeff); |
| free_var_coeff: |
| kfree(cpufreq_cdev->var_coeff); |
| err_mem: |
| return -ENOMEM; |
| } |
| |
| static int lookup_static_power(struct cpufreq_cooling_device *cpufreq_cdev, |
| unsigned long voltage, int temperature, u32 *power) |
| { |
| int volt_index = 0, temp_index = 0; |
| int index = 0; |
| int num_cpus; |
| int max_cpus; |
| struct cpufreq_policy *policy = cpufreq_cdev->policy; |
| cpumask_t tempmask; |
| |
| cpumask_and(&tempmask, policy->related_cpus, cpu_online_mask); |
| max_cpus = cpumask_weight(policy->related_cpus); |
| num_cpus = cpumask_weight(&tempmask); |
| voltage = voltage / 1000; |
| temperature = temperature / 1000; |
| |
| for (volt_index = 0; volt_index <= cpufreq_cdev->var_volt_size; volt_index++) { |
| if (voltage < cpufreq_cdev->var_table[volt_index * ((int)cpufreq_cdev->var_temp_size + 1)]) { |
| volt_index = volt_index - 1; |
| break; |
| } |
| } |
| |
| if (volt_index == 0) |
| volt_index = 1; |
| |
| if (volt_index > cpufreq_cdev->var_volt_size) |
| volt_index = cpufreq_cdev->var_volt_size; |
| |
| for (temp_index = 0; temp_index <= cpufreq_cdev->var_temp_size; temp_index++) { |
| if (temperature < cpufreq_cdev->var_table[temp_index]) { |
| temp_index = temp_index - 1; |
| break; |
| } |
| } |
| |
| if (temp_index == 0) |
| temp_index = 1; |
| |
| if (temp_index > cpufreq_cdev->var_temp_size) |
| temp_index = cpufreq_cdev->var_temp_size; |
| |
| index = (int)(volt_index * (cpufreq_cdev->var_temp_size + 1) + temp_index); |
| *power = (unsigned int)cpufreq_cdev->var_table[index]; |
| |
| return 0; |
| } |
| |
| static u32 cpu_freq_to_power(struct cpufreq_cooling_device *cpufreq_cdev, |
| u32 freq) |
| { |
| int i; |
| struct freq_table *freq_table = cpufreq_cdev->freq_table; |
| |
| for (i = 1; i <= cpufreq_cdev->max_level; i++) |
| if (freq > freq_table[i].frequency) |
| break; |
| |
| return freq_table[i - 1].power; |
| } |
| |
| static u32 cpu_power_to_freq(struct cpufreq_cooling_device *cpufreq_cdev, |
| u32 power) |
| { |
| int i; |
| struct freq_table *freq_table = cpufreq_cdev->freq_table; |
| |
| for (i = 0; i < cpufreq_cdev->max_level; i++) |
| if (power >= freq_table[i].power) |
| break; |
| |
| return freq_table[i].frequency; |
| } |
| |
| /** |
| * get_load() - get load for a cpu since last updated |
| * @cpufreq_cdev: &struct cpufreq_cooling_device for this cpu |
| * @cpu: cpu number |
| * @cpu_idx: index of the cpu in time_in_idle* |
| * |
| * Return: The average load of cpu @cpu in percentage since this |
| * function was last called. |
| */ |
| static u32 get_load(struct cpufreq_cooling_device *cpufreq_cdev, int cpu, |
| int cpu_idx) |
| { |
| u32 load; |
| u64 now, now_idle, delta_time, delta_idle; |
| struct time_in_idle *idle_time = &cpufreq_cdev->idle_time[cpu_idx]; |
| |
| now_idle = get_cpu_idle_time(cpu, &now, 0); |
| delta_idle = now_idle - idle_time->time; |
| delta_time = now - idle_time->timestamp; |
| |
| if (delta_time <= delta_idle) |
| load = 0; |
| else |
| load = div64_u64(100 * (delta_time - delta_idle), delta_time); |
| |
| idle_time->time = now_idle; |
| idle_time->timestamp = now; |
| |
| return load; |
| } |
| |
| /** |
| * get_static_power() - calculate the static power consumed by the cpus |
| * @cpufreq_cdev: struct &cpufreq_cooling_device for this cpu cdev |
| * @tz: thermal zone device in which we're operating |
| * @freq: frequency in KHz |
| * @power: pointer in which to store the calculated static power |
| * |
| * Calculate the static power consumed by the cpus described by |
| * @cpu_actor running at frequency @freq. This function relies on a |
| * platform specific function that should have been provided when the |
| * actor was registered. If it wasn't, the static power is assumed to |
| * be negligible. The calculated static power is stored in @power. |
| * |
| * Return: 0 on success, -E* on failure. |
| */ |
| static int get_static_power(struct cpufreq_cooling_device *cpufreq_cdev, |
| struct thermal_zone_device *tz, unsigned long freq, |
| u32 *power) |
| { |
| struct dev_pm_opp *opp; |
| unsigned long voltage; |
| struct cpufreq_policy *policy = cpufreq_cdev->policy; |
| unsigned long freq_hz = freq * 1000; |
| struct device *dev; |
| cpumask_t tempmask; |
| int num_cpus, max_cpus; |
| u32 raw_cpu_power; |
| |
| *power = 0; |
| |
| dev = get_cpu_device(policy->cpu); |
| |
| if (!dev) |
| return 0; |
| |
| opp = dev_pm_opp_find_freq_exact(dev, freq_hz, true); |
| if (IS_ERR(opp)) { |
| dev_warn_ratelimited(dev, "Failed to find OPP for frequency %lu: %ld\n", |
| freq_hz, PTR_ERR(opp)); |
| return -EINVAL; |
| } |
| |
| voltage = dev_pm_opp_get_voltage(opp); |
| dev_pm_opp_put(opp); |
| |
| if (voltage == 0) { |
| dev_err_ratelimited(dev, "Failed to get voltage for frequency %lu\n", |
| freq_hz); |
| return -EINVAL; |
| } |
| |
| lookup_static_power(cpufreq_cdev, voltage, tz->temperature, &raw_cpu_power); |
| |
| cpumask_and(&tempmask, policy->related_cpus, cpu_online_mask); |
| num_cpus = cpumask_weight(&tempmask); |
| max_cpus = cpumask_weight(policy->related_cpus); |
| |
| *power = (raw_cpu_power * (num_cpus + 1)) / (max_cpus + 1); |
| |
| return 0; |
| } |
| |
| /** |
| * get_dynamic_power() - calculate the dynamic power |
| * @cpufreq_cdev: &cpufreq_cooling_device for this cdev |
| * @freq: current frequency |
| * |
| * Return: the dynamic power consumed by the cpus described by |
| * @cpufreq_cdev. |
| */ |
| static u32 get_dynamic_power(struct cpufreq_cooling_device *cpufreq_cdev, |
| unsigned long freq) |
| { |
| u32 raw_cpu_power; |
| |
| raw_cpu_power = cpu_freq_to_power(cpufreq_cdev, freq); |
| return (raw_cpu_power * cpufreq_cdev->last_load) / 100; |
| } |
| |
| /* cpufreq cooling device callback functions are defined below */ |
| |
| /** |
| * cpufreq_get_max_state - callback function to get the max cooling state. |
| * @cdev: thermal cooling device pointer. |
| * @state: fill this variable with the max cooling state. |
| * |
| * Callback for the thermal cooling device to return the cpufreq |
| * max cooling state. |
| * |
| * Return: 0 on success, an error code otherwise. |
| */ |
| static int cpufreq_get_max_state(struct thermal_cooling_device *cdev, |
| unsigned long *state) |
| { |
| struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata; |
| |
| *state = cpufreq_cdev->max_level; |
| return 0; |
| } |
| |
| /** |
| * cpufreq_get_cur_state - callback function to get the current cooling state. |
| * @cdev: thermal cooling device pointer. |
| * @state: fill this variable with the current cooling state. |
| * |
| * Callback for the thermal cooling device to return the cpufreq |
| * current cooling state. |
| * |
| * Return: 0 on success, an error code otherwise. |
| */ |
| static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev, |
| unsigned long *state) |
| { |
| struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata; |
| |
| *state = cpufreq_cdev->cpufreq_state; |
| |
| return 0; |
| } |
| |
| /** |
| * cpufreq_set_cur_state - callback function to set the current cooling state. |
| * @cdev: thermal cooling device pointer. |
| * @state: set this variable to the current cooling state. |
| * |
| * Callback for the thermal cooling device to change the cpufreq |
| * current cooling state. |
| * |
| * Return: 0 on success, an error code otherwise. |
| */ |
| static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev, |
| unsigned long state) |
| { |
| struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata; |
| unsigned int clip_freq; |
| |
| /* Request state should be less than max_level */ |
| if (WARN_ON(state > cpufreq_cdev->max_level)) |
| return -EINVAL; |
| |
| /* Check if the old cooling action is same as new cooling action */ |
| if (cpufreq_cdev->cpufreq_state == state) |
| return 0; |
| |
| clip_freq = cpufreq_cdev->freq_table[state].frequency; |
| cpufreq_cdev->cpufreq_state = state; |
| cpufreq_cdev->clipped_freq = clip_freq; |
| |
| cpufreq_update_policy(cpufreq_cdev->policy->cpu); |
| |
| return 0; |
| } |
| |
| static int exynos_cpufreq_cooling_get_level(struct thermal_cooling_device *cdev, |
| unsigned long value) |
| { |
| struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata; |
| int level = get_level(cpufreq_cdev, value); |
| |
| if (level == THERMAL_CSTATE_INVALID && value > cpufreq_cdev->freq_table[0].frequency) |
| level = 0; |
| |
| return level; |
| } |
| |
| /** |
| * cpufreq_get_requested_power() - get the current power |
| * @cdev: &thermal_cooling_device pointer |
| * @tz: a valid thermal zone device pointer |
| * @power: pointer in which to store the resulting power |
| * |
| * Calculate the current power consumption of the cpus in milliwatts |
| * and store it in @power. This function should actually calculate |
| * the requested power, but it's hard to get the frequency that |
| * cpufreq would have assigned if there were no thermal limits. |
| * Instead, we calculate the current power on the assumption that the |
| * immediate future will look like the immediate past. |
| * |
| * We use the current frequency and the average load since this |
| * function was last called. In reality, there could have been |
| * multiple opps since this function was last called and that affects |
| * the load calculation. While it's not perfectly accurate, this |
| * simplification is good enough and works. REVISIT this, as more |
| * complex code may be needed if experiments show that it's not |
| * accurate enough. |
| * |
| * Return: 0 on success, -E* if getting the static power failed. |
| */ |
| static int cpufreq_get_requested_power(struct thermal_cooling_device *cdev, |
| struct thermal_zone_device *tz, |
| u32 *power) |
| { |
| unsigned long freq; |
| int i = 0, cpu, ret; |
| u32 static_power, dynamic_power, total_load = 0; |
| struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata; |
| struct cpufreq_policy *policy = cpufreq_cdev->policy; |
| u32 *load_cpu = NULL; |
| |
| freq = cpufreq_quick_get(policy->cpu); |
| |
| if (freq == 0) { |
| *power = 0; |
| return 0; |
| } |
| |
| if (trace_thermal_power_cpu_get_power_enabled()) { |
| u32 ncpus = cpumask_weight(policy->related_cpus); |
| |
| load_cpu = kcalloc(ncpus, sizeof(*load_cpu), GFP_KERNEL); |
| } |
| |
| for_each_cpu(cpu, policy->related_cpus) { |
| u32 load; |
| |
| if (cpu_online(cpu)) |
| load = get_load(cpufreq_cdev, cpu, i); |
| else |
| load = 0; |
| |
| total_load += load; |
| if (load_cpu) |
| load_cpu[i] = load; |
| |
| i++; |
| } |
| |
| cpufreq_cdev->last_load = total_load; |
| |
| dynamic_power = get_dynamic_power(cpufreq_cdev, freq); |
| ret = get_static_power(cpufreq_cdev, tz, freq, &static_power); |
| if (ret) { |
| kfree(load_cpu); |
| return ret; |
| } |
| |
| if (load_cpu) { |
| trace_thermal_power_cpu_get_power(tz->id, policy->related_cpus, freq, |
| load_cpu, i, dynamic_power, |
| static_power); |
| |
| kfree(load_cpu); |
| } |
| |
| *power = static_power + dynamic_power; |
| return 0; |
| } |
| |
| /** |
| * cpufreq_state2power() - convert a cpu cdev state to power consumed |
| * @cdev: &thermal_cooling_device pointer |
| * @tz: a valid thermal zone device pointer |
| * @state: cooling device state to be converted |
| * @power: pointer in which to store the resulting power |
| * |
| * Convert cooling device state @state into power consumption in |
| * milliwatts assuming 100% load. Store the calculated power in |
| * @power. |
| * |
| * Return: 0 on success, -EINVAL if the cooling device state could not |
| * be converted into a frequency or other -E* if there was an error |
| * when calculating the static power. |
| */ |
| static int cpufreq_state2power(struct thermal_cooling_device *cdev, |
| struct thermal_zone_device *tz, |
| unsigned long state, u32 *power) |
| { |
| unsigned int freq, num_cpus; |
| u32 static_power, dynamic_power; |
| int ret; |
| struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata; |
| |
| /* Request state should be less than max_level */ |
| if (WARN_ON(state > cpufreq_cdev->max_level)) |
| return -EINVAL; |
| |
| num_cpus = cpumask_weight(cpufreq_cdev->policy->cpus); |
| |
| freq = cpufreq_cdev->freq_table[state].frequency; |
| dynamic_power = cpu_freq_to_power(cpufreq_cdev, freq) * num_cpus; |
| ret = get_static_power(cpufreq_cdev, tz, freq, &static_power); |
| if (ret) |
| return ret; |
| |
| *power = static_power + dynamic_power; |
| return ret; |
| } |
| |
| /** |
| * cpufreq_power2state() - convert power to a cooling device state |
| * @cdev: &thermal_cooling_device pointer |
| * @tz: a valid thermal zone device pointer |
| * @power: power in milliwatts to be converted |
| * @state: pointer in which to store the resulting state |
| * |
| * Calculate a cooling device state for the cpus described by @cdev |
| * that would allow them to consume at most @power mW and store it in |
| * @state. Note that this calculation depends on external factors |
| * such as the cpu load or the current static power. Calling this |
| * function with the same power as input can yield different cooling |
| * device states depending on those external factors. |
| * |
| * Return: 0 on success, -ENODEV if no cpus are online or -EINVAL if |
| * the calculated frequency could not be converted to a valid state. |
| * The latter should not happen unless the frequencies available to |
| * cpufreq have changed since the initialization of the cpu cooling |
| * device. |
| */ |
| static int cpufreq_power2state(struct thermal_cooling_device *cdev, |
| struct thermal_zone_device *tz, u32 power, |
| unsigned long *state) |
| { |
| unsigned int cpu, cur_freq, target_freq; |
| int ret; |
| s32 dyn_power; |
| u32 normalised_power, static_power; |
| struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata; |
| struct cpufreq_policy *policy = cpufreq_cdev->policy; |
| cpumask_t tempmask; |
| int num_cpus; |
| |
| cpumask_and(&tempmask, policy->related_cpus, cpu_online_mask); |
| num_cpus = cpumask_weight(&tempmask); |
| |
| cpu = cpumask_first(&tempmask); |
| |
| /* None of our cpus are online */ |
| if (cpu >= nr_cpu_ids) |
| return -ENODEV; |
| |
| cur_freq = cpufreq_quick_get(policy->cpu); |
| ret = get_static_power(cpufreq_cdev, tz, cur_freq, &static_power); |
| if (ret) |
| return ret; |
| |
| dyn_power = power - static_power; |
| dyn_power = dyn_power > 0 ? dyn_power : 0; |
| normalised_power = dyn_power / num_cpus; |
| target_freq = cpu_power_to_freq(cpufreq_cdev, normalised_power); |
| |
| *state = cpufreq_cooling_get_level(cpu, target_freq); |
| if (*state == THERMAL_CSTATE_INVALID) { |
| dev_warn_ratelimited(&cdev->device, |
| "Failed to convert %dKHz for cpu %d into a cdev state\n", |
| target_freq, cpu); |
| return -EINVAL; |
| } |
| |
| *state = get_level(cpufreq_cdev, target_freq); |
| trace_thermal_power_cpu_limit(tz->id, policy->related_cpus, target_freq, *state, |
| power); |
| return 0; |
| } |
| |
| static int cpufreq_set_cur_temp(struct thermal_cooling_device *cdev, |
| bool suspended, int temp) |
| { |
| enum tmu_noti_state_t tstate; |
| unsigned int on; |
| |
| if (suspended || temp < EXYNOS_COLD_TEMP) { |
| tstate = TMU_COLD; |
| on = 1; |
| } else { |
| tstate = TMU_NORMAL; |
| on = 0; |
| } |
| |
| if (cpu_tstate == tstate) |
| return 0; |
| |
| cpu_tstate = tstate; |
| |
| blocking_notifier_call_chain(&cpu_notifier, TMU_COLD, &on); |
| |
| return 0; |
| } |
| |
| /* Bind cpufreq callbacks to thermal cooling device ops */ |
| |
| static struct thermal_cooling_device_ops cpufreq_cooling_ops = { |
| .get_max_state = cpufreq_get_max_state, |
| .get_cur_state = cpufreq_get_cur_state, |
| .set_cur_state = cpufreq_set_cur_state, |
| .get_cooling_level = exynos_cpufreq_cooling_get_level, |
| .set_cur_temp = cpufreq_set_cur_temp, |
| }; |
| |
| static struct thermal_cooling_device_ops cpufreq_power_cooling_ops = { |
| .get_max_state = cpufreq_get_max_state, |
| .get_cur_state = cpufreq_get_cur_state, |
| .set_cur_state = cpufreq_set_cur_state, |
| .get_requested_power = cpufreq_get_requested_power, |
| .state2power = cpufreq_state2power, |
| .power2state = cpufreq_power2state, |
| .set_cur_temp = cpufreq_set_cur_temp, |
| }; |
| |
| /* Notifier for cpufreq policy change */ |
| static struct notifier_block thermal_cpufreq_notifier_block = { |
| .notifier_call = cpufreq_thermal_notifier, |
| }; |
| |
| int exynos_tmu_add_notifier(struct notifier_block *n) |
| { |
| return blocking_notifier_chain_register(&cpu_notifier, n); |
| } |
| |
| static unsigned int find_next_max(struct cpufreq_frequency_table *table, |
| unsigned int prev_max) |
| { |
| struct cpufreq_frequency_table *pos; |
| unsigned int max = 0; |
| |
| cpufreq_for_each_valid_entry(pos, table) { |
| if (pos->frequency > max && pos->frequency < prev_max) |
| max = pos->frequency; |
| } |
| |
| return max; |
| } |
| |
| /** |
| * __cpufreq_cooling_register - helper function to create cpufreq cooling device |
| * @np: a valid struct device_node to the cooling device device tree node |
| * @policy: cpufreq policy |
| * Normally this should be same as cpufreq policy->related_cpus. |
| * @capacitance: dynamic power coefficient for these cpus |
| * @plat_static_func: function to calculate the static power consumed by these |
| * cpus (optional) |
| * |
| * This interface function registers the cpufreq cooling device with the name |
| * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq |
| * cooling devices. It also gives the opportunity to link the cooling device |
| * with a device tree node, in order to bind it via the thermal DT code. |
| * |
| * Return: a valid struct thermal_cooling_device pointer on success, |
| * on failure, it returns a corresponding ERR_PTR(). |
| */ |
| static struct thermal_cooling_device * |
| __cpufreq_cooling_register(struct device_node *np, |
| struct cpufreq_policy *policy, u32 capacitance, |
| get_static_t plat_static_func) |
| { |
| struct thermal_cooling_device *cdev; |
| struct cpufreq_cooling_device *cpufreq_cdev; |
| char dev_name[THERMAL_NAME_LENGTH]; |
| unsigned int freq, i, num_cpus; |
| int ret; |
| struct thermal_cooling_device_ops *cooling_ops; |
| bool first; |
| |
| if (IS_ERR_OR_NULL(policy)) { |
| pr_err("%s: cpufreq policy isn't valid: %p", __func__, policy); |
| return ERR_PTR(-EINVAL); |
| } |
| |
| i = cpufreq_table_count_valid_entries(policy); |
| if (!i) { |
| pr_debug("%s: CPUFreq table not found or has no valid entries\n", |
| __func__); |
| return ERR_PTR(-ENODEV); |
| } |
| |
| cpufreq_cdev = kzalloc(sizeof(*cpufreq_cdev), GFP_KERNEL); |
| if (!cpufreq_cdev) |
| return ERR_PTR(-ENOMEM); |
| |
| cpufreq_cdev->policy = policy; |
| num_cpus = cpumask_weight(policy->related_cpus); |
| cpufreq_cdev->idle_time = kcalloc(num_cpus, |
| sizeof(*cpufreq_cdev->idle_time), |
| GFP_KERNEL); |
| if (!cpufreq_cdev->idle_time) { |
| cdev = ERR_PTR(-ENOMEM); |
| goto free_cdev; |
| } |
| |
| /* max_level is an index, not a counter */ |
| cpufreq_cdev->max_level = i - 1; |
| |
| cpufreq_cdev->freq_table = kmalloc_array(i, |
| sizeof(*cpufreq_cdev->freq_table), |
| GFP_KERNEL); |
| if (!cpufreq_cdev->freq_table) { |
| cdev = ERR_PTR(-ENOMEM); |
| goto free_idle_time; |
| } |
| |
| ret = ida_simple_get(&cpufreq_ida, 0, 0, GFP_KERNEL); |
| if (ret < 0) { |
| cdev = ERR_PTR(ret); |
| goto free_table; |
| } |
| cpufreq_cdev->id = ret; |
| |
| snprintf(dev_name, sizeof(dev_name), "thermal-cpufreq-%d", |
| cpufreq_cdev->id); |
| |
| /* Fill freq-table in descending order of frequencies */ |
| for (i = 0, freq = -1; i <= cpufreq_cdev->max_level; i++) { |
| freq = find_next_max(policy->freq_table, freq); |
| cpufreq_cdev->freq_table[i].frequency = freq; |
| |
| /* Warn for duplicate entries */ |
| if (!freq) |
| pr_warn("%s: table has duplicate entries\n", __func__); |
| else |
| pr_debug("%s: freq:%u KHz\n", __func__, freq); |
| } |
| |
| if (capacitance) { |
| ret = update_freq_table(cpufreq_cdev, capacitance); |
| if (ret) { |
| cdev = ERR_PTR(ret); |
| goto remove_ida; |
| } |
| |
| ret = build_static_power_table(np, cpufreq_cdev); |
| if (ret) { |
| cdev = ERR_PTR(ret); |
| goto remove_ida; |
| } |
| |
| cooling_ops = &cpufreq_power_cooling_ops; |
| } else { |
| cooling_ops = &cpufreq_cooling_ops; |
| } |
| |
| cdev = thermal_of_cooling_device_register(np, dev_name, cpufreq_cdev, |
| cooling_ops); |
| if (IS_ERR(cdev)) |
| goto remove_ida; |
| |
| cpufreq_cdev->clipped_freq = cpufreq_cdev->freq_table[0].frequency; |
| cpufreq_cdev->cdev = cdev; |
| |
| mutex_lock(&cooling_list_lock); |
| /* Register the notifier for first cpufreq cooling device */ |
| first = list_empty(&cpufreq_cdev_list); |
| list_add(&cpufreq_cdev->node, &cpufreq_cdev_list); |
| mutex_unlock(&cooling_list_lock); |
| |
| if (first) |
| cpufreq_register_notifier(&thermal_cpufreq_notifier_block, |
| CPUFREQ_POLICY_NOTIFIER); |
| |
| return cdev; |
| |
| remove_ida: |
| ida_simple_remove(&cpufreq_ida, cpufreq_cdev->id); |
| free_table: |
| kfree(cpufreq_cdev->freq_table); |
| free_idle_time: |
| kfree(cpufreq_cdev->idle_time); |
| free_cdev: |
| kfree(cpufreq_cdev); |
| return cdev; |
| } |
| |
| /** |
| * cpufreq_cooling_register - function to create cpufreq cooling device. |
| * @policy: cpufreq policy |
| * |
| * This interface function registers the cpufreq cooling device with the name |
| * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq |
| * cooling devices. |
| * |
| * Return: a valid struct thermal_cooling_device pointer on success, |
| * on failure, it returns a corresponding ERR_PTR(). |
| */ |
| struct thermal_cooling_device * |
| cpufreq_cooling_register(struct cpufreq_policy *policy) |
| { |
| return __cpufreq_cooling_register(NULL, policy, 0, NULL); |
| } |
| EXPORT_SYMBOL_GPL(cpufreq_cooling_register); |
| |
| /** |
| * of_cpufreq_cooling_register - function to create cpufreq cooling device. |
| * @np: a valid struct device_node to the cooling device device tree node |
| * @policy: cpufreq policy |
| * |
| * This interface function registers the cpufreq cooling device with the name |
| * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq |
| * cooling devices. Using this API, the cpufreq cooling device will be |
| * linked to the device tree node provided. |
| * |
| * Return: a valid struct thermal_cooling_device pointer on success, |
| * on failure, it returns a corresponding ERR_PTR(). |
| */ |
| struct thermal_cooling_device * |
| of_cpufreq_cooling_register(struct device_node *np, |
| struct cpufreq_policy *policy) |
| { |
| if (!np) |
| return ERR_PTR(-EINVAL); |
| |
| return __cpufreq_cooling_register(np, policy, 0, NULL); |
| } |
| EXPORT_SYMBOL_GPL(of_cpufreq_cooling_register); |
| |
| /** |
| * cpufreq_power_cooling_register() - create cpufreq cooling device with power extensions |
| * @policy: cpufreq policy |
| * @capacitance: dynamic power coefficient for these cpus |
| * @plat_static_func: function to calculate the static power consumed by these |
| * cpus (optional) |
| * |
| * This interface function registers the cpufreq cooling device with |
| * the name "thermal-cpufreq-%x". This api can support multiple |
| * instances of cpufreq cooling devices. Using this function, the |
| * cooling device will implement the power extensions by using a |
| * simple cpu power model. The cpus must have registered their OPPs |
| * using the OPP library. |
| * |
| * An optional @plat_static_func may be provided to calculate the |
| * static power consumed by these cpus. If the platform's static |
| * power consumption is unknown or negligible, make it NULL. |
| * |
| * Return: a valid struct thermal_cooling_device pointer on success, |
| * on failure, it returns a corresponding ERR_PTR(). |
| */ |
| struct thermal_cooling_device * |
| cpufreq_power_cooling_register(struct cpufreq_policy *policy, u32 capacitance, |
| get_static_t plat_static_func) |
| { |
| return __cpufreq_cooling_register(NULL, policy, capacitance, |
| plat_static_func); |
| } |
| EXPORT_SYMBOL(cpufreq_power_cooling_register); |
| |
| /** |
| * of_cpufreq_power_cooling_register() - create cpufreq cooling device with power extensions |
| * @np: a valid struct device_node to the cooling device device tree node |
| * @policy: cpufreq policy |
| * @capacitance: dynamic power coefficient for these cpus |
| * @plat_static_func: function to calculate the static power consumed by these |
| * cpus (optional) |
| * |
| * This interface function registers the cpufreq cooling device with |
| * the name "thermal-cpufreq-%x". This api can support multiple |
| * instances of cpufreq cooling devices. Using this API, the cpufreq |
| * cooling device will be linked to the device tree node provided. |
| * Using this function, the cooling device will implement the power |
| * extensions by using a simple cpu power model. The cpus must have |
| * registered their OPPs using the OPP library. |
| * |
| * An optional @plat_static_func may be provided to calculate the |
| * static power consumed by these cpus. If the platform's static |
| * power consumption is unknown or negligible, make it NULL. |
| * |
| * Return: a valid struct thermal_cooling_device pointer on success, |
| * on failure, it returns a corresponding ERR_PTR(). |
| */ |
| struct thermal_cooling_device * |
| of_cpufreq_power_cooling_register(struct device_node *np, |
| struct cpufreq_policy *policy, |
| u32 capacitance, |
| get_static_t plat_static_func) |
| { |
| if (!np) |
| return ERR_PTR(-EINVAL); |
| |
| return __cpufreq_cooling_register(np, policy, capacitance, |
| plat_static_func); |
| } |
| EXPORT_SYMBOL(of_cpufreq_power_cooling_register); |
| |
| /** |
| * cpufreq_cooling_unregister - function to remove cpufreq cooling device. |
| * @cdev: thermal cooling device pointer. |
| * |
| * This interface function unregisters the "thermal-cpufreq-%x" cooling device. |
| */ |
| void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev) |
| { |
| struct cpufreq_cooling_device *cpufreq_cdev; |
| bool last; |
| |
| if (!cdev) |
| return; |
| |
| cpufreq_cdev = cdev->devdata; |
| |
| mutex_lock(&cooling_list_lock); |
| list_del(&cpufreq_cdev->node); |
| /* Unregister the notifier for the last cpufreq cooling device */ |
| last = list_empty(&cpufreq_cdev_list); |
| mutex_unlock(&cooling_list_lock); |
| |
| if (last) |
| cpufreq_unregister_notifier(&thermal_cpufreq_notifier_block, |
| CPUFREQ_POLICY_NOTIFIER); |
| |
| thermal_cooling_device_unregister(cpufreq_cdev->cdev); |
| ida_simple_remove(&cpufreq_ida, cpufreq_cdev->id); |
| kfree(cpufreq_cdev->idle_time); |
| kfree(cpufreq_cdev->freq_table); |
| kfree(cpufreq_cdev); |
| } |
| EXPORT_SYMBOL_GPL(cpufreq_cooling_unregister); |
| |
| struct thermal_cooling_device * |
| exynos_cpufreq_cooling_register(struct device_node *np, struct cpufreq_policy *policy) |
| { |
| struct thermal_zone_device *tz; |
| void *gen_block; |
| struct ect_gen_param_table *pwr_coeff; |
| u32 capacitance = 0; |
| |
| if (!np) |
| return ERR_PTR(-EINVAL); |
| |
| tz = thermal_zone_get_zone_by_cool_np(np); |
| |
| if (tz) { |
| gen_block = ect_get_block("GEN"); |
| if (gen_block == NULL) { |
| pr_err("%s: Failed to get gen block from ECT\n", __func__); |
| goto regist; |
| } |
| pwr_coeff = ect_gen_param_get_table(gen_block, "DTM_PWR_Coeff"); |
| if (pwr_coeff == NULL) { |
| pr_err("%s: Failed to get power coeff from ECT\n", __func__); |
| goto regist; |
| } |
| capacitance = pwr_coeff->parameter[tz->id]; |
| } else { |
| pr_err("%s: could not find thermal zone\n", __func__); |
| } |
| |
| regist: |
| return __cpufreq_cooling_register(np, policy, capacitance, |
| NULL); |
| } |
| EXPORT_SYMBOL_GPL(exynos_cpufreq_cooling_register); |