OMAP2/3: I2C: Errata ID i207: Clear wrong RDR interrupt

Under certain rare conditions, I2C_STAT[13].RDR bit may be set
and the corresponding interrupt fire, even there is no data in
the receive FIFO, or the I2C data transfer is still ongoing.
These spurious RDR events must be ignored by the software.

This patch handles and ignores RDR spurious interrupts.

The below sequence is required in interrupt handler for
handling this errata:
1. If RDR is set to 1, clear RDR
2. Read I2C status register and check for BusBusy bit. If BusBusy
bit is set, skip remaining steps.
3. If BusBusy bit is not set, perform read operation on I2C status
register.
4. If RDR is set, clear the same. Check RDR again and clear if it sets
RDR bit again.
5. Perform I2C Data Read operation N number of times(where N is value
read from the register BUFSTAT-RXSTAT bit fields).

Note:
This errata is not applicable for omap2420 and omap4.
It is applicable for:
1. omap2430
2. omap34xx(including omap3630).

Signed-off-by: Manjunatha GK <manjugk@ti.com>
Cc: Hema Kalliguddi <hemahk@ti.com>
Cc: Nishanth Menon <nm@ti.com>
Cc: Aaro Koskinen <Aaro.Koskinen@nokia.com>
Signed-off-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Ben Dooks <ben-linux@fluff.org>
1 file changed