hwmon: (ibmpowernv) replace AMBIENT_TEMP by TEMP
Ambient is too restrictive as there can be other temperature channels :
core, memory, etc.
Signed-off-by: Cédric Le Goater <clg@fr.ibm.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
diff --git a/drivers/hwmon/ibmpowernv.c b/drivers/hwmon/ibmpowernv.c
index febe817..f691e18 100644
--- a/drivers/hwmon/ibmpowernv.c
+++ b/drivers/hwmon/ibmpowernv.c
@@ -44,7 +44,7 @@
*/
enum sensors {
FAN,
- AMBIENT_TEMP,
+ TEMP,
POWER_SUPPLY,
POWER_INPUT,
MAX_SENSOR_TYPE,
@@ -87,7 +87,7 @@
return ret;
/* Convert temperature to milli-degrees */
- if (sdata->type == AMBIENT_TEMP)
+ if (sdata->type == TEMP)
x *= 1000;
/* Convert power to micro-watts */
else if (sdata->type == POWER_INPUT)
@@ -154,7 +154,7 @@
} else if (!strcmp(attr_suffix, DT_DATA_ATTR_SUFFIX)) {
attr_name = "input";
} else if (!strcmp(attr_suffix, DT_THRESHOLD_ATTR_SUFFIX)) {
- if (type == AMBIENT_TEMP)
+ if (type == TEMP)
attr_name = "max";
else if (type == FAN)
attr_name = "min";