dcdbas.txt: standardize document format

Each text file under Documentation follows a different
format. Some doesn't even have titles!

Change its representation to follow the adopted standard,
using ReST markups for it to be parseable by Sphinx:

- Mark titles;
- Mark literal blocks;
- Mark table.

Signed-off-by: Mauro Carvalho Chehab <mchehab@osg.samsung.com>
Signed-off-by: Jonathan Corbet <corbet@lwn.net>
diff --git a/Documentation/dcdbas.txt b/Documentation/dcdbas.txt
index e1c52e2..309cc57 100644
--- a/Documentation/dcdbas.txt
+++ b/Documentation/dcdbas.txt
@@ -1,4 +1,9 @@
+===================================
+Dell Systems Management Base Driver
+===================================
+
 Overview
+========
 
 The Dell Systems Management Base Driver provides a sysfs interface for
 systems management software such as Dell OpenManage to perform system
@@ -17,6 +22,7 @@
 
 
 System Management Interrupt
+===========================
 
 On some Dell systems, systems management software must access certain
 management information via a system management interrupt (SMI).  The SMI data
@@ -24,12 +30,12 @@
 buffer is required for the SMI.  The driver maintains the memory required for
 the SMI and provides a way for the application to generate the SMI.
 The driver creates the following sysfs entries for systems management
-software to perform these system management interrupts:
+software to perform these system management interrupts::
 
-/sys/devices/platform/dcdbas/smi_data
-/sys/devices/platform/dcdbas/smi_data_buf_phys_addr
-/sys/devices/platform/dcdbas/smi_data_buf_size
-/sys/devices/platform/dcdbas/smi_request
+	/sys/devices/platform/dcdbas/smi_data
+	/sys/devices/platform/dcdbas/smi_data_buf_phys_addr
+	/sys/devices/platform/dcdbas/smi_data_buf_size
+	/sys/devices/platform/dcdbas/smi_request
 
 Systems management software must perform the following steps to execute
 a SMI using this driver:
@@ -43,6 +49,7 @@
 
 
 Host Control Action
+===================
 
 Dell OpenManage supports a host control feature that allows the administrator
 to perform a power cycle or power off of the system after the OS has finished
@@ -69,12 +76,14 @@
 
 
 Host Control SMI Type
+=====================
 
 The following table shows the value to write to host_control_smi_type to
 perform a power cycle or power off host control action:
 
+=================== =====================
 PowerEdge System    Host Control SMI Type
-----------------    ---------------------
+=================== =====================
       300             HC_SMITYPE_TYPE1
      1300             HC_SMITYPE_TYPE1
      1400             HC_SMITYPE_TYPE2
@@ -87,5 +96,4 @@
      1655MC           HC_SMITYPE_TYPE2
       700             HC_SMITYPE_TYPE3
       750             HC_SMITYPE_TYPE3
-
-
+=================== =====================